EM Test CWS 500N1 Continuous Wave Simulator

Manufacturer part number: CWS-500N1
EM Test CWS 500N1 Continuous Wave Simulator for IEC 61000-4-6
PURCHASE
Available QTY Price
New:   0
+ -
$0.00
Used:   0
+ -
$0.00 Configurations
X

Available Configurations

The CWS 500N1.3 is the most compact single box test equipment for testing conducted rf immunity per IEC 61000-4-6 Ed. 3 and Ed. 4 and related standards with a frequency range of 10 kHz to 400 MHz. Apart from the 1 kHz 80 % AM signal the generator also generates a 2 Hz 80 % AM signal to test medical appliances and a 1 Hz PM signal with 50 % duty cycle
required to test safety equipment like fire alarms.

Equipped with a 1 GHz current monitor the CWS 500N1.3 can be used up to 1 GHz by means of an external amplifier. EM TEST supplies a large range of CDNs, EM clamp and current injection clamps as well as the corresponding calibration accessories. Full compliant levelling can be run from the front panel of the CWS 500N1.3 storing the results in 5 memory spaces is available.

  • 9kHz to 1GHz Signal Generator 
  • Amplitude modulation: 1Hz to 3kHz (0% to 95%)
  • Pulse modulation: 1Hz - 1kHz (10% to 90%)
  • Built-in amplifier, 100kHz to 300MHz 
  • Built-in current monitor, 9kHz to 1GHz  

Output

  • Output Level: 1 V - max. 30 V (emf) all standard test levels are guaranteed with all coupling methods
  • Output PowerL 80 W (49 dBm) at 1 dB compression
  • Output Impedance: 50 ohm
  • Harmonic Distortion: < -20 dBc at max. power
  • Amplifier Gain: 48 dB
  • Output Impedance: 50 ohm
  • Direct RF Output: N connector (on front panel)

Test Frequencies

  • Sinus (CW): 10 kHz to 400 MHz
  • Unmodulated Signal: CW (continuous wave)
  • Amplitude Modulation: 1 kHz, 80 % AM per IEC 61000-4-6; 2 Hz, 80 % AM per IEC 60601-1-2; 400 Hz, 80 % AM
  • Pulse Modulation: 1Hz, 50% duty cycle per EN 50130-4

Measurements

  • Monitor: Integrated RF power meter, measuring input for CDN and clamp calibration as well as current monitor for clamp applications
  • RF Indicator: LED indicating the RF output status
  • LCD: Online display of the test level and the preselected frequency value
  • Cal Data F1 - F5: 5 internal memories to save calibration data, 1% step width as required by the standards

Time Parameters

  • Dwell Time for CW & AM: td = 0.3s to 9,999s
  • Dwell Time for PM: td = 3s to 9,999s
  • Pause Time: tr = 0/0.3s to 9,999s

Test Routines

  • Quick Start: Immediate test start
  • User Test Routines: Voltage sweep, frequency sweep, dwell time sweep
  • Standard Test Routines: Level 1 to Level 3 (IEC 61000-4-6); Automatic Level X to Level Y
  • Cal Procedure: Calibration of the complete test set up, calibration data saved in internal memory

General Data

  • Dimensions: 19"/3 HU
  • Weight: Approx. 17 kg
  • Supply Voltage: 115 V to 230 V +10/-15 %, 50/60 Hz
  • Input Power: Max. 380 W
  • Power Factor: cos (phi) = 0.98 at max. output power as per IEC 555
  • Fuses: 2 x 6.3 AT (115 V) or 2 x 3.15 AT (230 V)
  • Cooling: Active cooling, air ventilation
  • Temperature: 10° C to 35° C
  • Rel. Humidity: Max. 85 %, non condensing
  • Atmospheric Pressure: 86 kPa (860 mbar) to 106 kPa (1,060 mbar)
Description

The CWS 500N1.3 is the most compact single box test equipment for testing conducted rf immunity per IEC 61000-4-6 Ed. 3 and Ed. 4 and related standards with a frequency range of 10 kHz to 400 MHz. Apart from the 1 kHz 80 % AM signal the generator also generates a 2 Hz 80 % AM signal to test medical appliances and a 1 Hz PM signal with 50 % duty cycle
required to test safety equipment like fire alarms.

Equipped with a 1 GHz current monitor the CWS 500N1.3 can be used up to 1 GHz by means of an external amplifier. EM TEST supplies a large range of CDNs, EM clamp and current injection clamps as well as the corresponding calibration accessories. Full compliant levelling can be run from the front panel of the CWS 500N1.3 storing the results in 5 memory spaces is available.

  • 9kHz to 1GHz Signal Generator 
  • Amplitude modulation: 1Hz to 3kHz (0% to 95%)
  • Pulse modulation: 1Hz - 1kHz (10% to 90%)
  • Built-in amplifier, 100kHz to 300MHz 
  • Built-in current monitor, 9kHz to 1GHz