The Keysight/Agilent/HP 11940A is a hand-held probe specially designed to measure magnetic field radiation from surface currents, slots, cable, and ICs for EMC diagnostic and troubleshooting measurements. Its unique design results in a high level of electric field rejection. This significantly reduces errors allowing calibrated and repeatable measurements. Each probe is calibrated and comes with a two-meter, RG-223 coaxial cable, an SMA (f) to Type-N (m) adapter, and an SMA (f) to BNC (m) adapter.

Features:

  • High level of electric field rejection
  • Allows calibrated and repeatable measurements
  • Maximum Input Power: 0.5 watts
  • Temperature Range: Variation over 0° C to +40° C
  • Dielectric Breakdown: ±1 kV, typical
  • Connector Type: SMA, replaceable barrel
  • VSWR:< 3:1, typical
  • Antenna Factor Accuracy: Individually calibrated to within ±2 dB in a 377 ohm field impedance
  • Antenna Factor: Measured for each unit at 30, 100, 500, 850, and 1000 MHz to within ± 2 dB in a 377 ohm field impedance
  • Temperature Range
    • Operating: 0°C to + 40°C : <± dB 
    • Storage: -10°C to +65°C 
  • Frequency Range: 30 MHz to 1 GHz
  • Connector: SMA, replaceable barrel
  • Maximum Input Power: 0.5 watts
  • VSWR: <3:1
  • Weight
    • Net: 0.10 kg (0.4 lbs)
    • Shipping: 0.56 kg (1.2 lbs)
  • Manual
  • Adapter, N(m) to SMA(f)
  • Adapter, BNC(m) to SMA(f)
  • Cable, M-M SMA 
Description

The Keysight/Agilent/HP 11940A is a hand-held probe specially designed to measure magnetic field radiation from surface currents, slots, cable, and ICs for EMC diagnostic and troubleshooting measurements. Its unique design results in a high level of electric field rejection. This significantly reduces errors allowing calibrated and repeatable measurements. Each probe is calibrated and comes with a two-meter, RG-223 coaxial cable, an SMA (f) to Type-N (m) adapter, and an SMA (f) to BNC (m) adapter.

Features:

  • High level of electric field rejection
  • Allows calibrated and repeatable measurements
  • Maximum Input Power: 0.5 watts
  • Temperature Range: Variation over 0° C to +40° C
  • Dielectric Breakdown: ±1 kV, typical
  • Connector Type: SMA, replaceable barrel
  • VSWR:< 3:1, typical
  • Antenna Factor Accuracy: Individually calibrated to within ±2 dB in a 377 ohm field impedance