Tektronix AM503S Current Probe

Manufacturer part number: AM503S
Consists of an AM 503/A Current Probe Amplifier, an A6302 Current Probe, and a TM 502A Power Module.
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

OPTIONS
NamePurchase
AM503A AMPLIFIER$0.00
AM503B PROBE AMPLIFIER$0.00
PLAIN$0.00
MAINFRAME & ACCESSORIES$0.00
MAINFRAME & ACCESSORIES$0.00
ADDS A6303, 100 AMP PROBE$0.00
SUB TM501A/502A-DEL TLBX$0.00
SUB A6303 PROBE$0.00
SUB A6312/A6302 REPLACES 50MHZ PROBE$0.00
DELETE A6302 -$735.00$0.00
SUB P6303 PROBE FOR A$0.00
CAL CERT$0.00

Tektronix AM503S Current Probe System

The Tektronix AM 503S Current Probe System consists of an AM 503/A Current Probe Amplifier, an A6302 Current Probe, and a TM 502A Power Module.

The AM 503S lets you use one probe to simultaneously measure AC and DC current. The AM 503A amplifier converts the sensed current into a proportional voltage signal that you can measure directly with an oscilloscope or similar measuring device. You can select the probe that best matches your application. Each probe uses a moveable slide to clamp around the conductor under test. The AM 503S provides better linearity than other current measurement systems because of a current feedback process used with the probe. DC measurement capability and high bandwidth allow the AM 503S to accurately represent square waves and fast-rise signals. The high sensitivity of the AM 503A maximizes measurement precision. In addition to the AM 503S system, you need an oscilloscope to display the AM 503S measurements. The oscilloscope bandwidth should be approximately four times the bandwidth of your current probe and should be capable of displaying a vertical scale factor of 10 mV/div.

Features:

  • Simultaneous AC/DC Measurements
  • DC to 100 MHz Bandwidths
  • Continuous Current Amplitudes from mA to 500 A (Peak to 700 A)
  • High Sensitivity
  • One Button Autobalance and Probe Degauss
  • Supports 6 Different Probes
  • No Need to Calibrate Amplifier with Specific Probes
  • GPIB Programmable (AM 5030)
  • AM 503A current probe amplifier
  • A6302 current probe (for optional probes, see options list)
  • TM 502A Power Module
  • Toolbox
  • AC power cord
  • BNC output cable
  • 50 Termination
  • User Manual and quick reference card
  • Bandwidth With A6302: DC to 50 MHz
  • Bandwidth With A6303: DC to 15 MHz
  • DC accuracy: ±3%
  • Rise time With A6302: ≤7 ns
  • Rise time With A6303: ≤23 ns
  • Aberrations: ±5%
  • Amp · Second product (unit of measure defining the maximum amount of pulsed current that can be measured before the probe core becomes saturated)
  • With A6302: 100 x 10-6 (100 A · µs)
  • With A6303: 10000 x 10-6 (10000 A · µs)
Description

Tektronix AM503S Current Probe System

The Tektronix AM 503S Current Probe System consists of an AM 503/A Current Probe Amplifier, an A6302 Current Probe, and a TM 502A Power Module.

The AM 503S lets you use one probe to simultaneously measure AC and DC current. The AM 503A amplifier converts the sensed current into a proportional voltage signal that you can measure directly with an oscilloscope or similar measuring device. You can select the probe that best matches your application. Each probe uses a moveable slide to clamp around the conductor under test. The AM 503S provides better linearity than other current measurement systems because of a current feedback process used with the probe. DC measurement capability and high bandwidth allow the AM 503S to accurately represent square waves and fast-rise signals. The high sensitivity of the AM 503A maximizes measurement precision. In addition to the AM 503S system, you need an oscilloscope to display the AM 503S measurements. The oscilloscope bandwidth should be approximately four times the bandwidth of your current probe and should be capable of displaying a vertical scale factor of 10 mV/div.

Features:

  • Simultaneous AC/DC Measurements
  • DC to 100 MHz Bandwidths
  • Continuous Current Amplitudes from mA to 500 A (Peak to 700 A)
  • High Sensitivity
  • One Button Autobalance and Probe Degauss
  • Supports 6 Different Probes
  • No Need to Calibrate Amplifier with Specific Probes
  • GPIB Programmable (AM 5030)