Contact us 800.813.8448

Recently added item(s) ×

You have no items in your shopping cart.

Teseq NSG 4070C Conducted Immunity Test System

Model Number: NSG 4070C

View Price / Get Quote

Teseq NSG 4070C Conducted Immunity Test System

Click on above image to view full picture

Condition

New

Availability
  • Quote to Rent/Lease
Description

Teseq NSG 4070C Conducted Immunity Test System

Available to Rent

In Stock

The NSG 4070, successor of the NSG 2070, is a multi-functional EMC immunity test system. Its wide frequency range from 9 kHz to 1 GHz and its modular design using internal or external amplifiers enable a large variety of applications including tests according to IEC/EN 61000-4-6, ISO 11452-4 and others. Powerful and easy to use firmware makes it possible to operate the NSG 4070 as a stand-alone unit. However, it can also be controlled remotely by external software as part of a system. Convenient test and measurement data transfer for documentation is provided by a USB stick which is plugged into the front panel.

All the possible coupling methods within the specified bandwidth, such as CDN (Coupling Decoupling Network) coupling clamp or a BCI (Bulk Current Injection) probe can be simply connected and calibrated. This eliminates the need for complex measurements on mostly non-linear coupling paths. During the calibration procedure the generator automatically corrects for any deviation and stores the correction details.

Various sweep modes are available which can be specifically selected to suit each particular test. In addition to the normal sweep applications, interference effects such as those caused by a pulsed interference source can be simulated in the pulse mode of operation.

Video

Test Standards
  •  CISPR 24
  •   EN 61000-6-1
  •   EN 61000-6-2
  •   IEC / EN 61000-4-21
  •   IEC / EN 61000-4-3
  •   IEC / EN 61000-4-6
  •   IEC 60533
  •   IEC 60601-1-2
  •   IEC 61326
  •   IEC/EN 61000–4–20
  •   ISO 11452-2
  •   ISO 11452-3
  •   ISO 11452-4
  •   ISO 11452-5
  •   RTCA/DO160
  •   SAE J1113-24
  •   SAE J1113-4
Specifications
    RF
  • Frequency range: 4 kHz to 1 GHz
  • Resolution: 1 Hz
  • Reference frequency: 10 MHz
  • Aging: 25 ppm
RF Level
  • Level range: -60 dBm to +10 dBm
  • Resolution: 0.1 dB
  • Settling time: 10 ms
Amplitude Modulation
  • Modulation depth: 0 to 100%
  • Modulation frequency range: 1 Hz to 50 kHz
  • Frequency resolution: 1 Hz
Pulse Modulation
  • Rise / fall time (10% / 90%): < 1 μs
  • Modulation frequency range: 0.01 Hz to 1 MHz
  • Frequency resolution: 0.01 Hz
  • Duty cycle: 0.1% to 100%
External Modulation
  • Delay time: < 1 μs / 180°
  • Period: min. 20 μs
  • Pulse width: min. 10 μs
Standard Accessories Included
  • Standard accessories included
For pricing, please request a quote.

Request a Quote