Com-Power LI-220A LISN

Manufacturer part number: LI-220A
For ISPR 16-1-2/ANSI C63.4, 9 kHz - 30 MHz.
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Key Features and Functions

The Com-Power LI-220A Line Impedance Stabilization Network (LISN) is in full compliance with both CISPR 16-1-2 and ANSI C63.4. It provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI- 220A performs each of the following functions during the measurement:

• provides a defined, stable impedance across the measure - ment frequency range; and,

• isolates the EUT and measurement circuit from the power source, thereby minimizing its influence on the measure - ments; and,

• couples the disturbance voltages to the coaxial measure - ment port for connection to the measuring instrument.

This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-220A is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current.

The LI-220A is a dual-conductor network capable of handling currents up to 20 Amps (AC) per line. The EUT power port is fitted with a universal, multi-configuration receptacle, which accomodates almost any EUT plug without the need for adapters. The power input port is fitted with a standard IEC C20 receptacle. As shown in the diagrams on the right, the LI-220A can be installed into any type of power system, including DC, single-phase, dual-phase and even three-phase systems.

Voltage Rating270 VAC (Line to Ground), 380 VDC
Frequency Range9 KHz - 30 MHz
Standards MetCISPR 16-1-2 / ANSI C63.4
RF Connector50Ω N-type (female)
Inductors250 & 50 microhenry (air-core)
Mains & EUT ConnectionsSuperior Electric SUPERCON® shrouded sockets
Current Rating20 Amperes AC, 14 Amperes DC
Application/Test TypePower line conducted emissions tests
Insertion Loss6 dB to 1 dB
Isolation20 dB to 40 dB
Dimensions16.75 x 15.5 x 7.5 inches / 42.5 x 39.3 x 19 cm
Weight20.5 lbs / 9.3 kg
Description

Key Features and Functions

The Com-Power LI-220A Line Impedance Stabilization Network (LISN) is in full compliance with both CISPR 16-1-2 and ANSI C63.4. It provides the necessary measurement platform for performing power line conducted emissions compliance testing as required by most worldwide standards for commercial products. The LI- 220A performs each of the following functions during the measurement:

• provides a defined, stable impedance across the measure - ment frequency range; and,

• isolates the EUT and measurement circuit from the power source, thereby minimizing its influence on the measure - ments; and,

• couples the disturbance voltages to the coaxial measure - ment port for connection to the measuring instrument.

This LISN uses air-core inductors to prevent saturation and permeability variation. The mounting plate of the LI-220A is left unpainted in order to facilitate connection to earth ground in its installation, which is essential due to high leakage current.

The LI-220A is a dual-conductor network capable of handling currents up to 20 Amps (AC) per line. The EUT power port is fitted with a universal, multi-configuration receptacle, which accomodates almost any EUT plug without the need for adapters. The power input port is fitted with a standard IEC C20 receptacle. As shown in the diagrams on the right, the LI-220A can be installed into any type of power system, including DC, single-phase, dual-phase and even three-phase systems.