Close
You have no items in your shopping cart.

Compliance West USA MegaPulse Defib-5P

Manufacturer part number: MEGAPULSE-DEFIB5P
Defib Proof Circuit Tester, 20k pulses
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

OPTIONS
NamePurchase
Energy Measurement Software$0.00
Production Test Package$0.00
Medical Safety Standard Option$0.00
IEC60601-2-49 Test Function Option$0.00
Defib-5 Pass-Fail$0.00
PLC Interface Board$0.00
High voltage probe$0.00
TestMinder for computer-conducted pulse$0.00
Vacuum Relay$0.00
Voltage Hold$0.00
240V Mains Power$0.00

Compliance West USA Defib-5 Defib Proof Circuit Tester

The Defib-5P uses an isolated USB/RS-232 solution. The USB connection on the computer side allows great flexibility for the use to connect to a wide variety of computers without the need for a special card or computer. On the test equipment side, the interface is RS-232, which offers a stronger, more error-free protocol for more trouble-free operation.

All waveforms can be delivered with a 5000V charge on the bulk capacitor. The front panel meter reads bulk capacitor voltage so it is clear when to fire the pulse. The 2kV pulse required by IEC 60601-2-2 is set with the front panel voltage knob. Output polarity is reversible with a front panel button.

  • Voltage rise time: 20µs
  • Voltage duration: 2200µs
  • Current rise time: 50µs
  • Current duration: 500µs
  • Meter accuracy: ±1%
  • Capacitor life: 20000 continuous cycles
  • Duty cycle: 30s at 5kV
  • Autotriger: optional
  • Continuous full voltage: optional
  • Testminder: optional
  • Energy calculation: optional
  • Data logging: optional
  • Mains: 120VAC, 50/60Hz
  • Manual
  • Test cables
  • Power cord
  • EC-11
  • EC-13
  • EC-53
  • IEC 60601-1
  • IEC 60601-2-2
  • IEC 60601-2-27
  • IEC 60601-2-30
  • IEC 60601-2-34
  • IEC 60601-2-49
Description

Compliance West USA Defib-5 Defib Proof Circuit Tester

The Defib-5P uses an isolated USB/RS-232 solution. The USB connection on the computer side allows great flexibility for the use to connect to a wide variety of computers without the need for a special card or computer. On the test equipment side, the interface is RS-232, which offers a stronger, more error-free protocol for more trouble-free operation.

All waveforms can be delivered with a 5000V charge on the bulk capacitor. The front panel meter reads bulk capacitor voltage so it is clear when to fire the pulse. The 2kV pulse required by IEC 60601-2-2 is set with the front panel voltage knob. Output polarity is reversible with a front panel button.