EM Test CWS 500N4 Simulator for Conducted, Common-Mode Disturbances

Manufacturer part number: CWS-500N4
EM Test CWS 500N4Simulator for conducted, common-mode disturbances, as per IEC 61000-4-16, IEC 61000-4-19 Annex C, 0Hz (DC) to 165kHz
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

CWS 500N4 - Testing for immunity to conducted, common-mode disturbances

The CWS 500N4 is the state-of-the-art solution in a compact single-box design to test for immunity to conducted, common mode disturbances in the frequency range 0Hz (DC) to 165kHz. Such test requirements are specified in IEC 61000-4-16 and cover continuous mode testing as well as short term testing with DC, 16 2/3Hz, 50Hz and 60Hz with 4 test levels each plus a sweep mode from 10Hz to 165kHz.
Additionally, the CWS 500N4 can be used for testing electricity metering equipment as per prTR 50579 and Draft standard IEC 61000-4-19, Annex C.
Features:
  • Most compact equipment for common-mode disturbances as per IEC 61000-4-16
  • Built-in LF signal generator and LF amplifier
  • Sweep mode capability 10Hz to 165kHz
  • Built-in rectifier module for DC testinge
  • Option for Electricity Meter testing acc IEC 61000-4-19 Annex C
  • Built-in voltage meter (rms values)
  • Test capabilities for DC, 16 2/3Hz, 50Hz and 60Hz in continuous mode and short term mode
  • USB-Interface
  • Built-in semiconductor power switch
  • Dimensions: 19"/6HU, 555mm x 448mm x 286mm
  • Weight: Approx. 30kg
  • Supply voltage: 115V - 230V +10/-15%, 50/60Hz
  • Input power: Max. 600W
  • Fuses: 2x6.3AT (115V) or 2x3.15AT (230V) 2x10AT for AC-source
  • Cooling: Active cooling, air ventilation
  • Temperature: 10°C - 40°C
  • EN 61000-4-16
  • IEC 60255-22-7
  • IEC 60255-26
  • IEC 60533
  • IEC 61000-4-16
  • IEC 61000-4-19, Annex C
  • IEC 61326
  • IEC 61543
  • IEC 61850-3
  • prTR 50579
Description

CWS 500N4 - Testing for immunity to conducted, common-mode disturbances

The CWS 500N4 is the state-of-the-art solution in a compact single-box design to test for immunity to conducted, common mode disturbances in the frequency range 0Hz (DC) to 165kHz. Such test requirements are specified in IEC 61000-4-16 and cover continuous mode testing as well as short term testing with DC, 16 2/3Hz, 50Hz and 60Hz with 4 test levels each plus a sweep mode from 10Hz to 165kHz.
Additionally, the CWS 500N4 can be used for testing electricity metering equipment as per prTR 50579 and Draft standard IEC 61000-4-19, Annex C.
Features:
  • Most compact equipment for common-mode disturbances as per IEC 61000-4-16
  • Built-in LF signal generator and LF amplifier
  • Sweep mode capability 10Hz to 165kHz
  • Built-in rectifier module for DC testinge
  • Option for Electricity Meter testing acc IEC 61000-4-19 Annex C
  • Built-in voltage meter (rms values)
  • Test capabilities for DC, 16 2/3Hz, 50Hz and 60Hz in continuous mode and short term mode
  • USB-Interface
  • Built-in semiconductor power switch