Teseq GTEM 1000 Test Cell

Test Cell complete with door and fan. 50W max. RF input. Outer dimensions 4.95x2.54x2.48m. Door size 0.75x0.60m. Max EUT size 0.74x0.74x0.66m. Fixed undercarriage.

A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 1000 has a maximum septum height of 1000mm and is suitable for emissions and immunity testing..

Features:

  • Emissions and immunity testing in a single, shielded environment
  • Meets basic standard: IEC/EN 61000-4-20
  • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
  • Meets standards for immunity testing: EN 60118-13
  • Ideal for design qualification and pre-certification
Test Standards
  •  CISPR 14-1
  •   EN 60118–13
  •   IEC 61000-4-2
  •   IEC 61000–6–3
  •   IEC 61000–6–4
  •   IEC/EN 61000–4–20
  •   ISO 11452-3
  •   SAE J1113-24
Specifications
  • Max. septum height: 1000mm
  • Septum height at marker position: 866mm
  • Dimension (LxWxH): 4.95 x 2.54 x 2.30m
  • Weight: ~790kg
  • Height of cell corpus: 1.73m
Standard Accessories Included
  • Calibration
  • Calibration certificate
  • Manual
  • All additional standard accessories