Key Features and Functions
The Fischer F-33-1 is for laboratory and field testing. This probe has a small outer diameter, approximately 71 mm with an internal diameter of 32 mm. The F-33-1 has a typical transfer impedance of 15 dBΩ (± 2 dB) over the frequency range of 70 kHz to 250 MHz. The RF current range is 10 amperes CW and 100 amperes peak with a duty cycle of 0.1. The maximum primary power line current is 100 amperes from DC – 400 Hz.
- Frequency: 10 kHz – 250 MHz
- Connector: Type-N
- Internal diameter: 32mm
- External diameter: 71mm
- Height: 19mm