Close
You have no items in your shopping cart.

AEMC Ground Resistance Test Kit for 4-Point Testing: 4630-2135.36

Manufacturer part number: 4630-2135.36
Test Kit for 4-Point Testing – 300ft: Used with a 4630 ground resistance tester
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

The Digital Ground Resistance Tester Model 4630 Kit performs ground resistance and soil resistivity tests. This direct reading testers measure from 0 to 2000O, and is auto-ranging, so it automatically seeks out the optimum measurement range. The Model 4630 Kit is rugged, easy-to-use and is ideal for maintenance crews performing numerous tests. It exceeds mechanical and safety specifications for shock, vibration and drop tests called out in IEC standards. It is designed to reject high levels of interference, so it can be used under difficult conditions such as high stray currents that normally affect accuracy. The Model 4620 Kit is powered by 9.6V, 3.5 Ah NiMH rechargeable batteries. A built-in recharge circuit, powered from 120/230V 50/60Hz line, also provides for testing while recharging.

The large LCD (nearly 3/4" high characters) is easy-to-read, and also indicates low battery status, over-range, and test lead shorts and lead reversals. Three LED indicators on the front panel continuously warn the user of measurement problems to ensure accurate and reliable tests. The Models 4620 is fuse protected up to 250VAC against accidental connection to live circuits. In the event of a system fault, they can withstand 250VAC with spikes of 3000VAC or 1000VDC.

The heavy-duty field case is sealed against dust and water when closed. The meter itself is self-contained within an inner case providing additional environmental and insulation protection. The test button is also sealed against the elements.

The Ground Resistance Tester Models 4630 is a rugged, easy-to-use instrument ideal for maintenance crews performing numerous tests. It exceeds mechanical and safety specifications for shock, vibration and drop tests called out in IEC standards. It's designed to reject high levels of interference, so it can be used under difficult conditions such as high stray currents that normally affect accuracy.

  • Model 4630 Ground Resistance Tester Kit - 300 ft
  • Measures soil resistivity (4-Point) method
  • Measures ground resistance (2- and 3-Point) Fall-of-Potential method
  • Step voltage tests and touch potential measurements
  • Auto-Ranging: automatically selects the optimum range
  • Designed to reject high levels of noise interference
  • Extremely simple to operate: connect - press - read
  • LED on faceplate informs the operator of high input noise, high auxiliary rod resistance, and fault connections
  • AC powered with rechargeable NiMH batteries
  • Rugged, dustproof and rainproof field case
  • Can also be used for continuity tests on bonding
  • Color-coded terminals
  • 120/230V 50/60Hz line cord
  • 300 ft. test lead on spool (RED)
  • 300 ft. test lead on spool (BLUE)
  • 100 ft. test lead (GREEN)
  • 100 ft. test lead (BLACK)
  • 5 ft. test lead (RED)
  • 5 ft. test lead (BLACK)
  • 14.5" T-shaped aux ground electrodes
  • Spaded lugs
  • Carrying bag
  • 100-foot measuring tape
Description

The Digital Ground Resistance Tester Model 4630 Kit performs ground resistance and soil resistivity tests. This direct reading testers measure from 0 to 2000O, and is auto-ranging, so it automatically seeks out the optimum measurement range. The Model 4630 Kit is rugged, easy-to-use and is ideal for maintenance crews performing numerous tests. It exceeds mechanical and safety specifications for shock, vibration and drop tests called out in IEC standards. It is designed to reject high levels of interference, so it can be used under difficult conditions such as high stray currents that normally affect accuracy. The Model 4620 Kit is powered by 9.6V, 3.5 Ah NiMH rechargeable batteries. A built-in recharge circuit, powered from 120/230V 50/60Hz line, also provides for testing while recharging.

The large LCD (nearly 3/4" high characters) is easy-to-read, and also indicates low battery status, over-range, and test lead shorts and lead reversals. Three LED indicators on the front panel continuously warn the user of measurement problems to ensure accurate and reliable tests. The Models 4620 is fuse protected up to 250VAC against accidental connection to live circuits. In the event of a system fault, they can withstand 250VAC with spikes of 3000VAC or 1000VDC.

The heavy-duty field case is sealed against dust and water when closed. The meter itself is self-contained within an inner case providing additional environmental and insulation protection. The test button is also sealed against the elements.

The Ground Resistance Tester Models 4630 is a rugged, easy-to-use instrument ideal for maintenance crews performing numerous tests. It exceeds mechanical and safety specifications for shock, vibration and drop tests called out in IEC standards. It's designed to reject high levels of interference, so it can be used under difficult conditions such as high stray currents that normally affect accuracy.

  • Model 4630 Ground Resistance Tester Kit - 300 ft
  • Measures soil resistivity (4-Point) method
  • Measures ground resistance (2- and 3-Point) Fall-of-Potential method
  • Step voltage tests and touch potential measurements
  • Auto-Ranging: automatically selects the optimum range
  • Designed to reject high levels of noise interference
  • Extremely simple to operate: connect - press - read
  • LED on faceplate informs the operator of high input noise, high auxiliary rod resistance, and fault connections
  • AC powered with rechargeable NiMH batteries
  • Rugged, dustproof and rainproof field case
  • Can also be used for continuity tests on bonding
  • Color-coded terminals
Product tags