Megger IDAX-300 Insulation Diagnostic Analyzer

Manufacturer part number: IDAX-300
IDAX 300 provides an accurate and reliable condition assessment of insulation in transformers, bushings, generators and cables. A system that maximizes the outcome of maintenance activities allowing for load and service life optimization.
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

IDAX 300 provides an accurate and reliable condition assessment of insulation in transformers, bushings, generators and cables. A system that maximizes the outcome of maintenance activities allowing for load and service life optimization.

IDAX 300 is smaller, lighter and faster than its predecessor IDAX 206. It maintains better accuracy and ability to provide reliable data using true DFR (Dielectric Frequency Response), also known as FDS (Frequency Domain Spectroscopy), without compromises. The state-of-the-art software makes testing both easier and faster, allowing transformer moisture assessment in less than 18 minutes.

IDAX 300 measures the capacitance and tan delta/power factor of the insulation between power transformer windings at multiple frequencies. Plotting the results as a curve makes it possible to assess the condition of the oil and solid insulation, assess the moisture level in the solid insulation and other potential insulation problems. The test can be performed at any temperature.

  • Mains Voltage: 100 – 240V ±10%, 50 / 60 Hz
  • Power Consumption: 250 VA (max)
  • Inputs: Red, blue, ground
  • Capacitance Range: 10 pF – 100 μF
  • Inaccuracy: 0.5% + 1 pF
  • Tan Delta Range: 0 - 100 (with retained accuracy of capacitance; otherwise higher)
  • Power Factor Range: 0 - 1 (with retained accuracy of capacitance; otherwise higher)
  • Max AC Interference: 1 mA, 1:10 SNR (IDAX); 10 mA, 1:10 SNR (VAX020)
  • Max DC Interference: 2 μA (IDAX) 20 μA (VAX020)
  • Dimensions: 335 x 300 x 99 mm (17.7” x 6.3” x 16.1”)
  • Weight: 4.9 kg (11 lbs)
Description

IDAX 300 provides an accurate and reliable condition assessment of insulation in transformers, bushings, generators and cables. A system that maximizes the outcome of maintenance activities allowing for load and service life optimization.

IDAX 300 is smaller, lighter and faster than its predecessor IDAX 206. It maintains better accuracy and ability to provide reliable data using true DFR (Dielectric Frequency Response), also known as FDS (Frequency Domain Spectroscopy), without compromises. The state-of-the-art software makes testing both easier and faster, allowing transformer moisture assessment in less than 18 minutes.

IDAX 300 measures the capacitance and tan delta/power factor of the insulation between power transformer windings at multiple frequencies. Plotting the results as a curve makes it possible to assess the condition of the oil and solid insulation, assess the moisture level in the solid insulation and other potential insulation problems. The test can be performed at any temperature.