Close
You have no items in your shopping cart.

Keysight/Agilent/HP 54701A Active Probe

Manufacturer part number: 54701A
The Agilent 54701A 2.5-GHz Active Probe is a probe solution for high-frequency applications. This probe is designed to be powered from a connector at the front of the oscilloscope, or with the 1143A Probe Offset Control and Power Module. It can be used with any measuring instrument with a 50-Ω input.
PURCHASE
AvailableQTYPrice
New:   1
+ -
$0.00
Used:   4
+ -
$259.00Configurations
X

Available Configurations

ACTIVE PROBE, 2.5GHZ/X10
30010713
$259
ACTIVE PROBE, 2.5GHZ/X10
30010714
$259
ACTIVE PROBE, 2.5GHZ/X10
30010715
$259
ACTIVE PROBE, 2.5GHZ/X10
30010716
$259

The 54701A is an Active Probe from Agilent. Use an electrical probe to test equipment and measure currents and voltages. Probes are an integral part of any electrical power testing toolbox to ensure accurate measurements, reliability, and safety. Probes can use pulse waveforms to test components without removing them from circuits with in-circuit capabilities. Choose the probe that complements your system.

Additional Features:

  • Attenuation Factor - 10:1
  • Bandwidth (-3dB) - > 2.5 GHz
  • Input Resistance - 100 k ohms
  • Rise Time - < 140 ps
  • Input Capacitance - 0.6 pF (typical)
  • Maximum Input Voltage - ± 200 V [DC + peak AC (< 20 MHz)]
  • ESD Tolerance (150 ohms/150 pF) - ± 12 kV
  • Dynamic Range - ± 5 V peak AC and ± 50 VDC
  • Offset Adjustment Range - ± 50 V
  • Alligator Ground Lead – 4in
  • Standard N (F) to BNC (M) Adapter
  • Mini-Probe Socket – Vertical
  • Connector, Probe Tips, Socket
  • Probe Socket
  • Sharp Probe Tips
  • Probe Tip
  • Carrying Case
  • Probe Flexible Adapter
  • 200 Ω Signal Lead – 2in
  • Manual
  • Leads – 2in
  • Walking Stick Ground
  • Driver, Nut; Probe Tip
Description

The 54701A is an Active Probe from Agilent. Use an electrical probe to test equipment and measure currents and voltages. Probes are an integral part of any electrical power testing toolbox to ensure accurate measurements, reliability, and safety. Probes can use pulse waveforms to test components without removing them from circuits with in-circuit capabilities. Choose the probe that complements your system.

Additional Features:

  • Attenuation Factor - 10:1
  • Bandwidth (-3dB) - > 2.5 GHz
  • Input Resistance - 100 k ohms
  • Rise Time - < 140 ps
  • Input Capacitance - 0.6 pF (typical)
  • Maximum Input Voltage - ± 200 V [DC + peak AC (< 20 MHz)]
  • ESD Tolerance (150 ohms/150 pF) - ± 12 kV
  • Dynamic Range - ± 5 V peak AC and ± 50 VDC
  • Offset Adjustment Range - ± 50 V