Close
You have no items in your shopping cart.

Keysight/Agilent/HP 8566B Spectrum Analyzer

Manufacturer part number: 8566B
100 Hz–22 GHz
PURCHASE
AvailableQTYPrice
New:   1
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

OPTIONS
NamePurchase
A/B CONVERSION$0.00
MATE COMPATIBLE SPEC AN$0.00
RF OUTPUT ON REAR PANEL 321.4$0.00
TURBO OPTION$0.00
RACK MOUNT SLIDE KIT$0.00
EMI RECEIVER FUNCTION$0.00
IMPULSE BW FOR EMI$0.00
QUASI PEAK I/O$0.00
5.25" OPS VERIFY DISK$0.00
HANDLE KIT W/O RACKMOUNT$0.00
RACK FLANGE KIT W/O HAND$0.00
HANDLE & RACK MOUNT KIT$0.00
EXTRA USER'S MANUALS$0.00
RANK FLANGE KIT W/HANDLE$0.00
Display Section for 8566B$0.00

Designed for bench and system use, the 8566B offers superior measurement speed, microwave frequency accuracy, and sensitivity. Measure low-level signals up to 22 GHz with narrow resolution bandwidths. Synthesizer stability virtually eliminates long-term drift and residual FM.

Frequency range is 100 Hz to 22 GHz with a dc-coupled input. Preselected external mixers extend this coverage from 26.5 to 75 GHz. Other external mixers allow measurement to 325 GHz.

An internal bus and microcomputer control make possible many powerful operating and data processing features, as well as flexibility under computer control. Sixteen Kbytes of user RAM are available for storing trace data, instrument states, and custom downloadable programs (DLPs). All displayed information can be sent directly to a plotter when sweeptime is greater than or equal to 20 ms.

  • Measurement range: 100 Hz to 22 GHz, dc-coupled input; up to 325 GHz with external mixers
  • Resolution bandwidth: 3 dB bandwidths of 10 Hz to 3 MHz in a 1. 3, 10 sequence. Bandwidth may be selected manually or coupled to frequency span (AUTO mode).
  • Power Requirements: 50 to 60 Hz; 100,200,120,220, or 240 V (+5%, -10%); approximately 650 VA (40 VA in standby). 400 Hz operation with Option 400.
  • Frequency Reference: Frequency reference aging rate attained after 24 hour warm-up from cold start at
    25 °C. Frequency is within 1 x 10'8 of final stabilized frequency within 30 minutes.
  • Temperature
    • Operation: 0° C to 55° C
    • Storage: -40° C to 75° C
  • Weight: 50 kg (112 lbs)
  • Dimensions: 626.4 x 457.2 x 279.2 mm (24.7 x 18 x 11 in)
  • Termination, Coaxial(Sma); 8562e
  • Power Cord
  • Opt 908: Rack Mount Kit, 5 1/4"
  • Opt 909: Rackmount With Handle, 6xxx Ser
  • Handle Kit, Front, 132.6(5.25)H
  • Opt 909: Rack Mount, W/Handles
  • IF Jumper Cable Assembly; 8566b
  • Cable, BNC To BNC, 4.5"
  • Cable, Coaxial Interconnect
  • Cable, W31 Interconnect Bus, 8566a
  • Disk, 3.5 EMI Software; 8566b/462
  • Disk, 5.25 EMI Software; 8566b/462
  • Overlay, Keyboard 85867a; 8566b
  • Template
  • Manual
Description

Designed for bench and system use, the 8566B offers superior measurement speed, microwave frequency accuracy, and sensitivity. Measure low-level signals up to 22 GHz with narrow resolution bandwidths. Synthesizer stability virtually eliminates long-term drift and residual FM.

Frequency range is 100 Hz to 22 GHz with a dc-coupled input. Preselected external mixers extend this coverage from 26.5 to 75 GHz. Other external mixers allow measurement to 325 GHz.

An internal bus and microcomputer control make possible many powerful operating and data processing features, as well as flexibility under computer control. Sixteen Kbytes of user RAM are available for storing trace data, instrument states, and custom downloadable programs (DLPs). All displayed information can be sent directly to a plotter when sweeptime is greater than or equal to 20 ms.