Keysight/Agilent 16910A Timing & State Logic Analysis Module

Manufacturer part number: 16910A
Keysight/Agilent 16910A 102-Channel 4 GHz Timing / 250 MHz State Logic Analysis Module
PURCHASE
AvailableQTYPrice
New:   1
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

OPTIONS
NamePurchase
INC MEMORY DEPTH 1M$0.00
INCR MEM DEPTH TO 4M$0.00
INCREASE MEMORY DEPTH TO 16M$0.00
MAX STATE SPEED 250MHZ$0.00
ACQ MEM 256K$0.00
INCREASE MAX ST SPEED 500MB/S$0.00

Timing Analysis (Asynchronous Sampling)

  • 4 GHz (250 ps) timing zoom with 64 K memory
  • 1.0 GHz / 500 MHz (half / full-channel) conventional timing analysis with deep memory
  • 500 MHz transitional timing

State Analysis (Synchronous Sampling)

  • State clock rates up to 450 MHz
  • Data rates: up to 500 Mb/s
  • Automated threshold/sample position setup for accurate measurements on high-speed buses
  • Simultaneous eye diagrams on all channels identify problem signals quickly

Configuration Considerations

  • 102-channels per module, combine up to 5 modules for 510 channels
  • Selectable memory depths: 1 M, 4 M, 16 M, 32 M Memory Depth and State Speed Upgrade Options
  • Compatible with 40-pin logic analyzer probes. Probes are ordered separately. Keysight’s Probe Recommendations
  • Compatible with 16900 Series modular logic analyzers

Additional Capabilities

  • Comprehensive single-ended signal support, threshold is adjustable from -5 V to 5 V (10 mV increments)
  • High-speed timing zoomL: 4 GHz (250 ps) with 64 K depth
  • Maximum timing sample rate: half channel mode: 1.0 GHz (1 ns)
  • Maximum timing sample rate: full channel mode: 500 MHz (2.0 ns)
  • Transitional timing: 500 MHz (2.0 ns)
  • Maximum state clock rate: 450 MHz with option 500, 250 MHz with option 250
  • Interconnect Flex Cable
Description

Timing Analysis (Asynchronous Sampling)

  • 4 GHz (250 ps) timing zoom with 64 K memory
  • 1.0 GHz / 500 MHz (half / full-channel) conventional timing analysis with deep memory
  • 500 MHz transitional timing

State Analysis (Synchronous Sampling)

  • State clock rates up to 450 MHz
  • Data rates: up to 500 Mb/s
  • Automated threshold/sample position setup for accurate measurements on high-speed buses
  • Simultaneous eye diagrams on all channels identify problem signals quickly

Configuration Considerations

  • 102-channels per module, combine up to 5 modules for 510 channels
  • Selectable memory depths: 1 M, 4 M, 16 M, 32 M Memory Depth and State Speed Upgrade Options
  • Compatible with 40-pin logic analyzer probes. Probes are ordered separately. Keysight’s Probe Recommendations
  • Compatible with 16900 Series modular logic analyzers

Additional Capabilities

  • Comprehensive single-ended signal support, threshold is adjustable from -5 V to 5 V (10 mV increments)