Close
You have no items in your shopping cart.

AEMC CA6121 Hipot/Insulation/Gnd Bond Tester

Manufacturer part number: CA6121
3KV/4KV AC HIPOT
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Key Features and Functions 

The AC and AC/DC High-Pot Testers are designed for safety and ease of operation, and readily adapt to development, maintenance and production testing. Three models are available: two ac and one ac/dc. These instruments test the dielectric strength of electrical insulation and the ground circuit continuity of three-wire appliances and other devices. They feature front-panel adjustable leakage current trip, one-second or continuous testing, and automatic failure shutdown.

  • Ground continuity check of three-wire devices with high-voltage interlock (ac models only)
  • Front-panel adjustable leakage current trip from 0.3 to 12 mA
  • One-second or continuous testing
  • Automatic failure shutdown, with visual and audible alarms
  • Recessed high-voltage connections
  • Front-panel NEMA 5-15R three-prong receptacle on ac models
  • Zero start/reset in event of failure
  • Meets UL 120-kΩ requirement
Input
  • Standard: 120 Vac ±10%, 1 A, 50/60 Hz
  • Optional: Nominal 230-Vac, 50/60-Hz line is available on all models for an additional charge. To order, add –47 to Cat. No.
Output
  • Maximum Output Current: 12.6 mA
  • Wave Shape
  • AC Models: Line
  • AC/DC Model: Maximum ripple 0.4% rms per mA at full voltage
Accuracy
  • Applied Test Voltage: ±2%
  • Leakage Current: ±5%
Description

Key Features and Functions 

The AC and AC/DC High-Pot Testers are designed for safety and ease of operation, and readily adapt to development, maintenance and production testing. Three models are available: two ac and one ac/dc. These instruments test the dielectric strength of electrical insulation and the ground circuit continuity of three-wire appliances and other devices. They feature front-panel adjustable leakage current trip, one-second or continuous testing, and automatic failure shutdown.

  • Ground continuity check of three-wire devices with high-voltage interlock (ac models only)
  • Front-panel adjustable leakage current trip from 0.3 to 12 mA
  • One-second or continuous testing
  • Automatic failure shutdown, with visual and audible alarms
  • Recessed high-voltage connections
  • Front-panel NEMA 5-15R three-prong receptacle on ac models
  • Zero start/reset in event of failure
  • Meets UL 120-kΩ requirement