Megger HT1000/2V Copper Wire Analyzer

Manufacturer part number: HT1000/2V
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Vectored DSL employs line signal coordination and noise cancellation to reduce crosstalk levels and improve line performance.

Using a Vectored DSL tester on non-vectored systems will not impinge on the test, using a non-vectored test instrument on a vectored system has a detrimental effect and can cause the system to crash.

The HT1000/2V is a high performance VDSL test instrument that provides copper wire provisioning and maintenance technicians with the most critical tests at the touch of a button.

Features

  • Vectored DSL testing for VDSL2 lines
  • Noise finder via a 30 MHz spectrum analyzer
  • 7 User selectable auto tests
  • Incremental pair test program
  • 200 pair pre-post test storage
  • AC or DC power

ACV: 0V to 250V (±2%, ± 1V)

DCV: 0V to ±300V (±2%, ±1V)

Resistance: 0 Ω to 1,000 KΩ (±2%, ±1 Ω)

Leakage: 1 MΩ to 999 MΩ (±3%), 150 V open circuit output

Longitudinal Balance: +30 dBrn to +80 dBrn (±2 dBrn)

Super Stress: -10 dBrn to +30 dBrn (±2 dBrn)

Load Coil Detection: 0 coil to 4 coils (±1 coil)

Loop Current: 0 mA to ±100 mA (±2%, ±1 mA)

Power Influence: +40 dBrnC to +100 dBrnC (±2 dBrnC)

Noise (Voice Band): 0 dBrnC to +60 dBrnC (±2 dBrnC)

Loss (Voice Band): -40 dBm to +10 dBm (±1 dBm)

Open Meter:

  • 0 m (0 ft) to 900 m (3,000 ft)
  • :±2%, ±1.5 m (5ft)
  • :900 m (3,000 ft) to 15 km (50,000 ft) (±3%)

Auto Test: 7 user-selectable auto test scripts, 200 pair storage, retest capability, Incremental pair testing program

Caller ID: Yes

ID Tone:

  • Frequency: 577.5 Hz (±1%)
  • Amplitude: 0 dBm, 600 Ω (±1 dBm)

Wideband Tone Send:

  • Frequency: 20 KHz to 9 MHz (±1%)
  • Amplitude: 0 dBm, 135 Ω (±1 dBm)

Wideband Tone Receive:

  • Frequency: 20 KHz to 33 MHz
  • Amplitude: -90 dBm, +2 dBm (±2 dBm)

Wideband Loss:

  • Frequency: 20 KHz to 33 MHz
  • Amplitude: -90 dBm, +2 dBm (±2 dBm) RFL
  • Distance to Fault: 0 – 3.000m (10,000 ft) ±0.5%, ±1m (3 ft)
  • Maximum Measurable Fault Resistance: 100 MΩ
  • Maximum Locatable Fault Resistance: 2 MΩ

TDR: Dual trace, 12 trace memory storage, Automatic pulse width selection, Pair comparison mode, Split/crosstalk mode, Intermittent fault location,mode, Intermittent fault location

  • Closest Range: 0 – 8 m (25 ft)
  • Longest Range: 0 – 16.000 m (49,000 ft) (@VOP = 0.7), Zoom mode

Wideband Spectrum analyzer:

  • Frequency: 20 KHz to 33 MHz
  • Amplitude: -90 dBm to +10 dBm (±2 dBm), -130 dBm/Hz to -30 dBm/Hz (±2 dBm/Hz)

Impulse noise:

  • Amplitude: -45 dBm to +10 dBm (±2 dBm)
  • Filters: F, G, J, None (30 MHz)

Voiceband Spectrum Analyzer:

  • Frequency: 50 Hz to 4,100 Hz
  • Amplitude: -64 dBm to 0 dBm (±2 dBm), -76 dBm/Hz to -12 dBm/Hz (±2 dBm/Hz)

Display: High resolution, 1/4 VGA graphics with LED backlight

Batteries: Rechargeable nickel-metal hydride

Battery Life: Approximately 30 hours typical usage

  • Test Lead Assembly
  • AC charger
  • Soft carrying case
  • DC charger
  • USB cord
Description

Vectored DSL employs line signal coordination and noise cancellation to reduce crosstalk levels and improve line performance.

Using a Vectored DSL tester on non-vectored systems will not impinge on the test, using a non-vectored test instrument on a vectored system has a detrimental effect and can cause the system to crash.

The HT1000/2V is a high performance VDSL test instrument that provides copper wire provisioning and maintenance technicians with the most critical tests at the touch of a button.

Features

  • Vectored DSL testing for VDSL2 lines
  • Noise finder via a 30 MHz spectrum analyzer
  • 7 User selectable auto tests
  • Incremental pair test program
  • 200 pair pre-post test storage
  • AC or DC power