Testing
Output:
- 0 - 32 kV (negative with regard to earth)
- 0 – 32 kV, 35 mA constant
- 0 – 16 kV, 65 mA constant
Resolution: 5 mA
Metering: Analog metering of current and voltage
Low-voltage Pre-location
MTDR100
Range: 10 ranges; 100 m – 55 km (328 ft - 34 miles) 100 m - 220 km (328 ft - 137 miles) - transient methods
Pulse width: 50, 100, 200, 500 ns, 1, 2,5,10 µs, and auto
Pulse Amplitude: 25 V into 50 Ω
Sampling Rate: 100 MHz
Timbase Accuracy: 200 ppm
Resolution: 0.82 m (2.8 ft)@ 82.5m / µsec
Display: 26.4 mm (10.4 in.), full XGA, 1024 X 768 color display
Cursors: Dual independent control
Gain: 60 dB range in 5 dB Steps
Input: Impedance 50 Ω
Inputs: 1 x TDR/ARC, 1 x current impulse
Ports: 1 x printer/USB memory device
Software: CAS1 (Cable analysis software)
High Voltage Pre-location
- Arc Reflection: 0-16 and 0-32 kV, 1500 Joule
- Arc Reflection Plus:
- 0-16 and 0-32 kV, 1500 Joule
- 1024 – 16 traces dependent on range
- Differential Arc Reflection: 0-16 and 0-32 kV, 1500 Joule
- Impulse Current: 0-16 and 0-32 kV, 1500 Joule
Fault Conditioning
Proof/burn:
- 0 - 32 kV 35 mA
- 0 - 16 kV 65 mA
Pinpoint Fault Location
- Surge: 0 - 16 and 0 -32 kV, @ 1500 Joule
- Impulse Sequence:
- Adjustable: 5 – 30 seconds
- Single Shot
Cables
- HV: Detachable 15 m (50 ft) 1-phase flexible shielded cable with HV crock-clips
- 120/230V Input/Supply: Input Cable
- Safety Ground: 15 m (50 ft) 8 mm2 flexible ground cable with vice grips
Safety
- High visibility “status” bar
- Emergency stop
- Safety Interlock circuit
- External beacon circuit (beacon optional)
Supply: Universal AVSM 2-ranges: 108 - 132 V ac and 208 - 265 V ac 47 – 63 Hz
Environmental
- Operating Temperature: -20 ° to +50 °C (-4 ° to 122 °F)
- Storage Temperature: -20 ° to +55 °C (-4 ° to 131 °F)
- Elevation: 1600 m (De-rate voltages at higher altitudes)
- Humidity: 5 to 95% RH non-condensing
IP Rating: IP64 (with top/back flaps closed)
Weight: 131 kgs (290 lbs)
Dimensions: 965 mm H x 536 mm W x 503 mm D (38 in. H x 21 in. W x 20 in. D)