Features

  • Output DC Voltage – 200, 400VDC
  • Output Frequency – DC, 30 to 100Hz
  • Programmable 1, 2 or 3-Phase modes
  • Full 4 quadrant AC source operation
  • High-resolution waveform capture on all V & I
  • Sink power regenerated back to the facility
  • 9” Touch-Panel user interface
  • SCPI programming & NI LabVIEW drivers

Advantages

  • Bi-directional AC – Inverter testing & μgrid simulation
  • More reactive power per kW
  • Simplifies automated test stand development
    – Software selectable 1, 2, or 3 Phase operation
    – Isolated digital inputs & outputs
    – Built-in SW watchdog & safety limits
  • Software tools to shorten test development time
    – PC-based tools & NI certified drivers
    – NI Certified LabVIEW & IVI-C/IVI-COM drivers
    – Optional: Enerchron® test sequencer

Benefits

  • Regenerative, returns greater than 85% of power to the facility, which provides significant electrical savings.
  • Field upgradeable to a higher power
  • Fully emulate any utility/grid condition
  • Simulate non-ideal Phase phase angles (A-B & A-C)

  • Phases/Output Channels: 1, 2, or 3
  • Power, Max (1Φ or 3Φ): 12kW/24kVA
  • Current Ranges (RMS per Φ): 6, 30 A/Φ
  • Current Ranges (RMS 1Φ): 18, 90A
  • Peak Current: 3 X Max RMS
  • Frequency: 30-100Hz (option up to 880Hz)
  • Voltage Ranges, L-N: 175, 350V (Split Phase 250V Max)
  • Accuracy: 0.2% Set + 0.2% Rng
  • Resolution: 0.005% Rng
  • Distortion (THD): <1% @ 50/60Hz (Full power into resistive load at 480 VRMS (L-L))
  • Response Rate: 1V/µS (10% to 90% measured at 90 degree turn-on into resistive load)
  • Custom Waveforms: Sine, n-Step Sine, Triangle, Clipped-Sine, Arbitrary (user defined)
  • Phase Angle Control: 0 to 359 degrees/1 degree resolution
Description

 


Features

  • Output DC Voltage – 200, 400VDC
  • Output Frequency – DC, 30 to 100Hz
  • Programmable 1, 2 or 3-Phase modes
  • Full 4 quadrant AC source operation
  • High-resolution waveform capture on all V & I
  • Sink power regenerated back to the facility
  • 9” Touch-Panel user interface
  • SCPI programming & NI LabVIEW drivers

Advantages

  • Bi-directional AC – Inverter testing & μgrid simulation
  • More reactive power per kW
  • Simplifies automated test stand development
    – Software selectable 1, 2, or 3 Phase operation
    – Isolated digital inputs & outputs
    – Built-in SW watchdog & safety limits
  • Software tools to shorten test development time
    – PC-based tools & NI certified drivers
    – NI Certified LabVIEW & IVI-C/IVI-COM drivers
    – Optional: Enerchron® test sequencer

Benefits

  • Regenerative, returns greater than 85% of power to the facility, which provides significant electrical savings.
  • Field upgradeable to a higher power
  • Fully emulate any utility/grid condition
  • Simulate non-ideal Phase phase angles (A-B & A-C)