Close
You have no items in your shopping cart.

Phenix Technologies PAD10-25 Hipot/Megohmmeter

Manufacturer part number: PAD10-25
Phenix Technologies PAD10-25 Hipot/Megohmmeter 10kVAC/25kVDC
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

The Model PAD10-25 gives the operator the versatility of either AC or DC testing capability in one compact package. This unit will measure both megohms or leakage current in the DC mode and AC milliamps in the AC mode. The Hipots offered are suitable for lab or field use and are especially helpful when it is necessary to return equipment to a safe operating condition. This test set is conservatively designed and ruggedly built for use in testing switchgear, cables, motors, generators and many other devices.

Features

  • Large, easy to read meters
  • Adjustable overcurrent trip point
  • Continuously adjustable output
  • Guard circuit for stray leakage current bypass
  • Surge and transient protection
  • 10' output leads
  • External interlock provision
  • Zero start interlock
  • HV ON/OFF push buttons with indicators
  • Direct megohm readings
  • Visual and audible overload indicator
  • 3 range voltmeter
  • 4 range ammeter
  • Input: 120 Volts AC, 50/60 Hz, single phase, 1.2 Amps; 220 Volts AC, 50/60 Hz, single phase, .6 Amps
  • Output: 0-10 kV AC, up to 10 mA; 0-25 kV DC, negative, up to 5 mA
  • Output Polarity (DC): Negative output, positive ground
  • Duty Cycle: 1 hour ON/1 hour OFF at full power levels
  • Operating Ambient Temperature: 10-38°C, 50-100°F
  • Termination
    • Input: removable modular style 3 wire cord
    • High Voltage Output: 10’ shielded with insulated alligator clip
    • Return Lead: 10’ red lead with insulated alligator clip
    • Ground Lead: 10’ green lead with insulated alligator clip
  • Dimensions: 16.5” W x 15.25” D x 11.25” H (419 mm W x 388 mm D x 286 mm H
  • Weight: 36 lbs. (16.4 kg)
Description

The Model PAD10-25 gives the operator the versatility of either AC or DC testing capability in one compact package. This unit will measure both megohms or leakage current in the DC mode and AC milliamps in the AC mode. The Hipots offered are suitable for lab or field use and are especially helpful when it is necessary to return equipment to a safe operating condition. This test set is conservatively designed and ruggedly built for use in testing switchgear, cables, motors, generators and many other devices.

Features

  • Large, easy to read meters
  • Adjustable overcurrent trip point
  • Continuously adjustable output
  • Guard circuit for stray leakage current bypass
  • Surge and transient protection
  • 10' output leads
  • External interlock provision
  • Zero start interlock
  • HV ON/OFF push buttons with indicators
  • Direct megohm readings
  • Visual and audible overload indicator
  • 3 range voltmeter
  • 4 range ammeter