Radiated Immunity Test Systems

3 Items in Grid 4 Items in Grid List

A.H. Systems AK-2G Antenna Kit

FCC, MIL-STD, VDE and TEMPEST Testing up to 2 GHz

EM Test CWS 500N1.4 Test Generator

RF Conducted Immunity Test System

EM Test CWS 500N3 Test Generator

Key applications of the CWS 500N3 are in the automotive and aerospace area. Various international standards and MIL requirements call for magnetic field tests in the low frequency range. Apart from this the automotive industry requires conducted immunity tests with superposed sinusoidal signals on the DC supply voltage (ripple noise). For both applications the CWS 500N3 is the perfect equipment including everything in a single box, necessary for these tests. The CWS 500N3 meets requirements of SAE J1113-2, ISO 11452-8, DO 160D/E Section 18 and MIL-STD-461 D/E/F/G CS101, CS109 and RS101.

IFI SMC750 Solid State Amplifier

80 MHz to 1 GHz RF Amplifier

Teseq ITS 6006 Radiated Immunity Test System for IEC 61000-4-3

Integrated signal generator 80 MHz to 6 GHz

Teseq NSG 4060 Low Frequency Immunity Test System

The Teseq NSG 4060 is an EMC immunity test system for the frequency range of 15 Hz - 150 kHz

Teseq NSG 4070C-45 Compact Immunity Test System

Compact immunity test system NSG 4070C, 4 kHz–1 GHz RF generator and power meter (with integrated power amplifier 45 W module 9 kHz–1 GHz)

Teseq NSG 4070C-80 Compact Immunity Test System

With integrated power amplifier 80 W module 150 kHz–230 MHz

Fischer BCICF-1 Bulk Current Injection Probe Fixtures

Part of the test equipment required by most of the Bulk Current Injection test procedure specifications. Allows the user the quickly and easily calibrate the injection probe prior to performing compliance testing.

Fischer BCICF-2 Bulk Current Injection Probe Fixtures

Injection Probe calibration fixtures are a part of the test equipment required by most of the Bulk Current Injection Test Procedure Specifications. This test fixture allows the user to quickly and easily calibrate the injection probe prior to performing the compliance testing.

Fischer BCICF-6-150 Bulk Current Injection Probe Fixtures

Designed for the IEC 61000-4-6 Ed 4.0, section 6.2.3.1 – 6.2.3.2 that states “…the increase of the transmission loss of the test jig, produced by the insertion of the Current Clamp, shall not exceed 1.6 dB”. This 1.6 dB requirement is verified by subtracting the insertion loss of the calibration fixture without the Clamp in place from the fixture insertion loss with the Clamp in place.

Fischer F-120-1 Bulk Current Injection Probe

The Fischer Custom Communications FCC F-120-1 Bulk Current Injection Probe has been designed to extend the use of conducted immunity testing over the bandwidth of 10 kHz – 175 MHz

Fischer F-130A-1 Bulk Current Injection Probe

1MHz - 400MHz Frequency Used for BCI testing in accordance With automotive specifications like SAE J15447 CW input power rating is 100 watts for 30 minutes

Fischer F-140 Bulk Current Injection Probe

10 kHz – 1 GHz Frequency Used for BCI testing in accordance With automotive specifications like SAE J15447 Useable frequency range is 100 kHz – 1300 MHz With an insertion loss of less than 7 dB from 700 kHz to 500 MHz Input power rating is 100 watts for 30 minutes

Fischer FCC-BCICF-1 Bulk Current Injection Probe Fixtures

10 kHz – 400 MHz Frequency Injection Probe Calibration Fixtures Part of the test equipment required by most of the Bulk Current Injection test procedure specifications Calibration fixture allows the user the quickly Easily calibrate the injection probe prior to performing compliance testing

Fischer FCC-BCICF-2 Bulk Current Injection Probe Fixtures

10 kHz – 1 GHz Frequency Injection Probe Model Numbers: F-140, F-140A Injection Probe Calibration Fixtures Part of the test equipment required by most of the Bulk Current Injection test procedure specifications Test fixture allows the user to quickly and easily calibrate the injection probe

Fischer FCC-BCICF-6-150 Bulk Current Injection Probe Fixtures

150 kHz – 230 MHz Frequency Injection Probe calibration fixtures Part of the test equipment required by most of the Bulk Current Injection Test Procedure Specifications Allows the user to quickly and easily calibrate the injection probe prior to performing the compliance testing

M Precision DPI-1 Pin Injection Probe Set/Cable Accessories

Probe accessory kit suitable for all Waveforms to 5KV

Pearson D301X Current Probe

Current Probe to 50kA: 0.01V/A +/-1%; max rms current 400A with usable risetime from 200ns

Teseq CIP Current Injection Probe 4 kHz

Wide frequency range 4 kHz - 400 MHz High power handling (up to 1 kW) Ideal for automotive BCI testing e.g. ISO 11452-4, MIL-STD-461 CS114 and manufacture‘s requirements Meets IEC/EN 61000-4-6 Replacement for CIP 36A & 37A as specified in Defence Standard 59-41

Com-Power PC-114 EMC Pre-Compliance Emissions Test System

9 KHz - 1 GHz. Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz.