Close
You have no items in your shopping cart.

Haefely AXOS5 Compact Immunity Test System

Manufacturer part number: AXOS5
Haefely AXOS5 Compact Immunity Tester combines 5kV Burst/EFT, Surge combination wave, AC/DC Dips & Interrupts, along with an integrated single-phase coupling/decoupling network (CDN) into one compact system.
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

The AXOS 5 compact immunity test system integrates all of the best pieces of the Haefely stand-alone test systems into one single economic solution. It combines 5kV Burst/EFT, Surge combination wave, AC/DC Dips & Interrupts, along with an integrated single-phase coupling/decoupling network (CDN) into one compact system. It allows quick and completely automated testing to the most common IEC, EN, ANSI, IEEE, and UL standards including IEC 61000-4-29. The Haefely AXOS5 can either be operated via the front panel by a large color graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequent users.

Features:

  • Easy to operate with manual and automated test modes, software-assisted test preparation, pre-defined test routines, and visual aided test setups
  • Economic & Efficient: Touch  screen  guarantees  reduction of  time  and  effort - Experience and know-how at a reasonable price
  • Safe  and  reliable  operation  by  using safety  interlock,  warning  lamp, and emergency stop functions
  • Voltage  and  current  monitoring of surge  impulses  and  EUT  power  provides valuable feedback to the test engineer
  • Automatic generation of the test report, including test parameters, test setup and test result

  • IEC/EN 61000-4-4 EFT/Burst Ed 2&3
  • IEC/EN 61000-4-5 Surge Edition 2
  • Upcoming EC/EN 61000-4-5 Surge Edition 3
  • IEC/EN 61000-4-9 Imp Magnetic Field
  • IEC/EN 61000-4-11 AC Dip and Interrupt
  • IEC/EN 61000-4-29 DC Dip and Interrupt
  • IEC/EN 61000-6-1 Generic Residential
  • IEC/EN 61000-6-2 Generic Industrial
  • IEC/EN 60335-1 Household
  • IEC/EN 60601-1 Medical

General Specifications

  • User test storage: unlimited
  • Remote interface: Ethernet, RJ45
  • External memory: USB for USB memory stick
  • Display: 7in, 800x480, 24-bit, touch-screen
  • AUX interface: D-sub 37p for external CDN, external transformer etc
  • External trigger input: 5V TTL
  • Synch input: BNC, 10V to 264VAC
  • Trigger output: 5V TTL
  • External start/stop input: 5V TTL, starts/stops predefined test sequence
  • EUT failed input: 5V TTL
  • Analog output: 0 to 10V, for use with external options
  • Safety circuit: stops the test when unlocked
  • Control power: 85VAC to 264VAC, 50/60Hz
  • Dimensions, (W x H x D): 45 x 18 x 49cm; 19in/4U
  • Weight: 25kg

IEC/EN 61000-4-4 EDITION 2 & 3 EFT/BURST

  • Output voltage: 0.2 to 5.0kV ±10% at coaxial output
  • Spike frequency: 1Hz to 1MHz
  • Polarity: pos/neg/alternate
  • Burst duration: 10µs to 1s
  • Output impedance: 50Ω
  • Burst period: 1ms to 10s
  • Rise time: 5ns ±30%
  • Test time: 1s to 1000 minutes
  • Impulse duration at 50Ω: 50ns ±30%
  • Impulse duration at 1000Ω:50ns -15 +100ns
  • Trigger: automatic, manual, external trigger input
  • Burst mode: normal, continuous, real, random
  • Integrated single-phase coupling/decoupling network: 264VAC/16A; 220VDC/10A

IEC/EN 61000-4-5 EDITION 2 SURGE COMBINATION WAVE

  • Output voltage 0.2 to 5.0kV ±10%
  • Output current: 0.1 to 2.5kA ±10%
  • Voltage rise time: 1.2µs ±30%
  • Current rise time: 8µs ±20%
  • Voltage duration: 50µs ±20%
  • Current duration: 20µs ±20%
  • Polarity: pos/neg/alternate
  • Output impedance: 2Ω
  • Integrated single phase CDN: 264VAC/16A; 220VDC/10A
  • Phase sync: 0 to 359° with 1° steps or asynchronous mode
  • Impulse trigger: automatic 2s to 100 min, manual, external trigger input
  • Counter preselect: 1 to 1000/infinite
  • Counter: 100000
  • Peak voltage monitor: BNC output, 1000:1; display, 3 digits
  • Peak current monitor: BNC output, 1kA/V; display, 3 digits

IEC/EN 61000-4-11 EDITION 2 AND IEC/EN 61000-4-29 DIPS & INTERRUPTS

  • Max. voltage: 264VAC/DC
  • Interrupt time: 0.5 period to 800 periods, 100µs to 1000 minutes
  • Max. current: 16A AC/DC continuous
  • Max. current for 5s: 20A
  • Max. current for 3s: 23A
  • Max. current for 3s:40A >500A inrush current
  • Interval time 1: period to 800 periods synch; 100µs to 1000 minutes asynch
  • Trigger: automatic, manual, external trigger input
  • Test time: 1s to 1000 minutes, infinite
  • Interrupt dip level: 0%, 0% to 99% with external voltage source
  • Phase sync: 0 to 359° 16/40/50/60Hz asynchronous mode
  • User manual
  • Power cord
  • Cable, Banana(m) to Banana(m)
  • Six 4mm adaptors
Description

The AXOS 5 compact immunity test system integrates all of the best pieces of the Haefely stand-alone test systems into one single economic solution. It combines 5kV Burst/EFT, Surge combination wave, AC/DC Dips & Interrupts, along with an integrated single-phase coupling/decoupling network (CDN) into one compact system. It allows quick and completely automated testing to the most common IEC, EN, ANSI, IEEE, and UL standards including IEC 61000-4-29. The Haefely AXOS5 can either be operated via the front panel by a large color graphic interface or remotely from the PC. The easy to use menu together with the availability of predefined test routines for different standards makes testing easy and reliable, even for less frequent users.

Features:

  • Easy to operate with manual and automated test modes, software-assisted test preparation, pre-defined test routines, and visual aided test setups
  • Economic & Efficient: Touch  screen  guarantees  reduction of  time  and  effort - Experience and know-how at a reasonable price
  • Safe  and  reliable  operation  by  using safety  interlock,  warning  lamp, and emergency stop functions
  • Voltage  and  current  monitoring of surge  impulses  and  EUT  power  provides valuable feedback to the test engineer
  • Automatic generation of the test report, including test parameters, test setup and test result