Close
You have no items in your shopping cart.

Tektronix A6303 Current Probe

Manufacturer part number: A6303
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   1
+ -
$185.00Configurations
X

Available Configurations

CURRENT PROBE,15 MHZ
30005101
$185

The A6312, A6302, and A6303 offer a wide range of current measurement capability for the lab and bench environment. The A6312 covers frequencies from DC to 100 MHz while the A6302 covers DC to 50 MHz. Both clip onto conductors up to 3.81 mm (0.15 in.) and measure continuous currents up to 20 A and peak currents up to 50 A as long as they do not exceed the amp*second product of 100 A*μs.

The larger A6303 measures higher amplitude, lower frequency currents. It clips onto conductors up to 21.1 mm (0.83 in.) in diameter. Its frequency range is DC to 15 MHz. It will measure continuous currents up to 100 A and peak currents up to 500 A, as long as the amp*second product of 10,000 A*μs is not exceeded.

The A6302 and A6303 are also compatible with the 11A16 2-CH Current Probe Amplifier for the 11000 and DSA Series oscilloscopes. With the 11A16, the A6302 is rated for 10.5 A, and the A6303 for 52.5 A.

Features:

  • 2 Meter Cable
  • 100 Amps Continuous / 500 Amps Peak
  • DC to 15 MHz
  • Up to 0.83 in. Conductor Diameter
  • FOAM INSERT; W/CARDBOARD BOX: A6303 (TEK)
  • ML, INSTRUCTION;[DOWNLOAD] A6303 (TEK)
  • Calibration Certificate
  • Motor Drives
  • Satellite Systems
  • Inverters
  • Transportation Systems
  • Power Supplies
  • Avionics
Description

The A6312, A6302, and A6303 offer a wide range of current measurement capability for the lab and bench environment. The A6312 covers frequencies from DC to 100 MHz while the A6302 covers DC to 50 MHz. Both clip onto conductors up to 3.81 mm (0.15 in.) and measure continuous currents up to 20 A and peak currents up to 50 A as long as they do not exceed the amp*second product of 100 A*μs.

The larger A6303 measures higher amplitude, lower frequency currents. It clips onto conductors up to 21.1 mm (0.83 in.) in diameter. Its frequency range is DC to 15 MHz. It will measure continuous currents up to 100 A and peak currents up to 500 A, as long as the amp*second product of 10,000 A*μs is not exceeded.

The A6302 and A6303 are also compatible with the 11A16 2-CH Current Probe Amplifier for the 11000 and DSA Series oscilloscopes. With the 11A16, the A6302 is rated for 10.5 A, and the A6303 for 52.5 A.

Features:

  • 2 Meter Cable
  • 100 Amps Continuous / 500 Amps Peak
  • DC to 15 MHz
  • Up to 0.83 in. Conductor Diameter
Product tags