Tektronix P6417 General Purpose Probe

Manufacturer part number: P6417
17 Channel
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   3
+ -
$35.00Configurations
X

Available Configurations

GENERAL PURPOSE PROBE, 17 CHANNEL
10009200
$35
GENERAL PURPOSE PROBE, 17 CHANNEL
30005149
$35
GENERAL PURPOSE PROBE, 17 CHANNEL
30005150
$35

The P6417 and P6418 logic analyzer probes connect a Tektronix TLA Series logic analyzer to a target system. Each probe consists of 16 data channels and one clock/data channel. You can connect the probes to the target system through the podlet connectors or through the lead sets.

Features:

  • Threshold accuracy: ± 100 mV
  • Channel-to-channel-skew: ≤ 1 ns
  • Input resistance (probe and lead sets) Standard lead set: 20 KΩ
  • Reduced bias lead set: 10 KΩ
  • Input capacitance Data: 2.0 pF typical
  • Input capacitance Clock/Qual: 2.0 pF typical
  • Minimum slew rate: 0.2 ns
  • Maximum operating signal: 6.5 VP-P, --3.5 V absolute input voltage minimum, 6.5 V absolute input voltage maximum
  • Maximum nondestructive input signal to probe: ± 15 V
  • Minimum input pulse width signal: 2 ns
  • GRABBERS; 40V,Y(GREY); P6139A (TEK)
  • ML,INSTRUCTIONS;[DOWNLOAD]P6417/18 (TEK)
  • CABLE ASSY, 8 CHANNEL; TLA7L3 (TEK)
  • CABLE ASSY, 1 CHANNEL; TLA7L3 (TEK)
  • MARKER, PROBE ID; (CONSUM) P6417 (TEK)
  • Calibration Certificate
  • Threshold accuracy ± 100 mV
  • Channel-to-channel-skew ≤ 1 ns
  • Input resistance (probe and lead sets)
  • Standard lead set 20 KΩ
  • Reduced bias lead set 10 KΩ
  • Input capacitance Data: 2.0 pF typical
  • Input capacitance Clock/Qual: 2.0 pF typical
  • Minimum slew rate: 0.2 ns
  • Maximum nondestructive input signal to probe: ± 15 V
  • Minimum input pulse width signal: 2 ns
  • Delay from probe tip to module input connector: 7.33 ns
  • Probe length: 1.8 m (6 ft)
Description

The P6417 and P6418 logic analyzer probes connect a Tektronix TLA Series logic analyzer to a target system. Each probe consists of 16 data channels and one clock/data channel. You can connect the probes to the target system through the podlet connectors or through the lead sets.

Features:

  • Threshold accuracy: ± 100 mV
  • Channel-to-channel-skew: ≤ 1 ns
  • Input resistance (probe and lead sets) Standard lead set: 20 KΩ
  • Reduced bias lead set: 10 KΩ
  • Input capacitance Data: 2.0 pF typical
  • Input capacitance Clock/Qual: 2.0 pF typical
  • Minimum slew rate: 0.2 ns
  • Maximum operating signal: 6.5 VP-P, --3.5 V absolute input voltage minimum, 6.5 V absolute input voltage maximum
  • Maximum nondestructive input signal to probe: ± 15 V
  • Minimum input pulse width signal: 2 ns