Contact us 800.813.8448

Recently added item(s) ×

You have no items in your shopping cart.

Teledyne LeCroy HVD3605 High Voltage Differential Probe

Model Number: HVD3605

View Price / Get Quote

Teledyne LeCroy HVD3605 High Voltage Differential Probe

Click on above image to view full picture

Condition

Refurbished

Availability
  • Quote to Rent/Lease
  • Quote to Purchase
Description

HVD3605, 6kV, 100 MHz High Voltage Differential Probe

The HVD3605 is the only probe that permits AC line, DC Bus, and Drive/Inverter output voltage probing through 4160 V rating. It provides the industry’s best overshoot measurement capability (to 7600 Vpk) and the industry’s best offset capability of 6000 V when used with HDO Series oscilloscopes.

Key Features
  • 6 kV CAT safety rated
  • Widest differential voltage range available
  • Exceptional common-mode rejection ratio (CMRR) across a broad frequency range
  • 1% gain accuracy
  • High offset capability at both high and low attenuation
  • AC or DC coupling
  • 6 meter cable
  • ProBus active probe interface with automatic scaling
  • Auto-zero capabilities
  • Wide oscilloscope compatibility
Test Standards
  •  
Specifications
Main Specifications
  • Bandwidth: 100 MHz
  • Input Coupling: DC only
  • Input Impedance: 48 MΩ || 2.5 pF (between inputs), 24 MΩ || 5.0 pF (either input to ground)
  • Attenuation: 200x / 2000x
  • Rise Time (10-90%): 4.3 ns
  • Differential Voltage Range (High Attenuation): 7000 V (DC + peak AC) from 28 V/div to 2000 V/div with up to 6000V offset (7600 V maximum measurable differential voltage before saturation)
  • Differential Voltage Range (Low Attenuation): 700 (DC + peak AC) from 300 mV/div to 27.5 V/div with up to 600V offset.
  • Common Mode Voltage Range: ±7600 V (DC + peak AC), 6000 Vrms
  • Maximum Input Voltage to Earth: ±7600 Vpk (nominal, either input to ground)
  • Max Safe Input: 8485 V (DC + peak AC), 6000 Vrms, Both ratings CAT I per IEC/EN 61010-031/A1:2008, “O” Category (pending) per IEC/EN 61010-031:2015, 1500 Vdc CAT III (pending) per IEC/EN 61010-031:2015 1000 Vrms CAT III
  • Sensitivity: 300 mV/div to 27.5V/div (200X), 7V/div to 500V/div (2000X)
  • Gain Accuracy: 1% (LF, guaranteed)
  • Slew Rate: 1000 V/ns (maximum)
  • Output Coupling: AC or DC coupling
  • Output Termination: 1 MΩ
  • Interface: ProBus
  • Input Lead Length: 40 cm input lead length
  • Cable Length (input lead to oscilloscope connection): 6.8 m
Standard Accessories Included
  • 6 KV Safety Alligator Clips
  • Spade Terminals
  • Safety Alligator Clips
  • Plunger Alligator Clips
  • Plunger Pincer Clips
  • Plunger Hook Clips
$0.00

Request a Quote