Teseq CDN M5 5-Line Coupling Network

Manufacturer part number: CDN M5
For AC Power Lines 16-32 Amps
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Key Features and Functions

IEC/EN 61000-4-6 specifies the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).

  • 4 power lines, (2L+N+PE), (3L+PE), optional (3L+N)
  • Frequency range: 150 kHz to 230 MHz (optional 10 kHz - 80 MHz)
  • Designed for IEC/EN 61000-4-6
  • M4 application without PE
  • 4 mm banana sockets
  • Power Rating: 250VAC/400VDC line to ground

Voltage RatingAC max. voltage (line to ground) / (line to line): 250 V / 433 V (CDN M216-1000V: 500 V / 1000 V); DC max. voltage (line to ground) / (line to line): 400 V / 800 V (CDN M216-1000V: 1000 V / 2000 V); Test voltage: 3 kV DC, 2 sec
Frequency Range150 kHz to 230 MHz (Optional 10 kHz - 80 MHz)
Standards MetIEC 61000-4-6
RF ConnectorBNC, 50 Ω
Mains & EUT Connections4 mm, safety (Optional IEC 320 16A)
Current Rating32 Amps Maximum
Common Mode Impedance150 kHz to 26 MHz: 150 Ω ±20 Ω; 26 MHz to 230 MHz: 150 Ω +60 Ω / -45 Ω
Application/Test Type5 mains AC power lines emissions testing up to 32 Amps (3L+N+PE)
Insertion LossGreater than 0.1 dB
RF Input VoltageLess than 30 V
Voltage Division Factor10 dB +3 dB / -1 dB
Decoupling of Common Mode DisturbanceGreater than 30 dB
Dimensions6.3 x 6.3 x 20 inches (16.0 cm x 16.0 cm x 50.0 cm)
Weight6.5 kg (14.3 LB.'s)
Description

Key Features and Functions

IEC/EN 61000-4-6 specifies the design and performance of a range of coupling/decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq offers an extensive range of CDNs which fully comply with the requirements of the standard and provide a simple and reliable method of injecting RF energy into the equipment under test (EUT).

  • 4 power lines, (2L+N+PE), (3L+PE), optional (3L+N)
  • Frequency range: 150 kHz to 230 MHz (optional 10 kHz - 80 MHz)
  • Designed for IEC/EN 61000-4-6
  • M4 application without PE
  • 4 mm banana sockets
  • Power Rating: 250VAC/400VDC line to ground