With the CDND series, AMETEK CTS offers coupling and decoupling networks for feeding in differential interference. The Teseq CDND M316-2 is designed for differential voltage testing in the frequency range from 2 kHz to 150 kHz according to IEC/EN 61000-4-19.

IEC/EN 61000-4-19 specifies the differential voltage test in the frequency range 2 kHz to 150 kHz. Teseq offers with CDND M316-2 a coupling/decoupling network for single phase mains application. It can be used for both application with and without protective earth connection. The CDND is fully complaint with the requirements of the standard and provides a simple and reliable method of injecting RF energy into the equipment under test (EUT).

Key Features

  • Coupling networks designed for voltage test IEC/EN 61000-4-19
  • Frequency range 2 kHz to 150 kHz
  • 4 mm banana sockets
  • M2 and M3 applications
  • Frequency range: 2 kHz to 150 kHz
  • Power rating (EUT- and Mains port)
    • AC max. voltage (line to line/line to ground): 250 V/500 V (50 Hz /60 Hz)
    • DC max. voltage (line to line/line to ground): 300 V/500 V
    • Current max: 16 A
    • Test voltage: 1500 V DC, 2 sec
  • Common mode impedance (EUT port)
    • 2 kHz to 150 kHz: 10 Ω ±3 Ω
  • Coupling path (Generator/EUT port)
    • Connection: 4 mm banana
    • RF voltage (2 kHz to 150 kHz):
  • Voltage drop (Mains port to EUT port)
    • at 16 A DC: approx. 2.6 V
    • at 16 A AC (50 Hz): approx. 18 V
  • Decoupling of CM disturbance (Mains port/EUT port)
    • 2 kHz to 50 kHz: >10 dB to >50 dB
    • 50 kHz to 150 kHz: >50 dB
  • Size (W x H x D): 162 mm x 162 mm x 470 mm
  • Weight: approx. 10.4 kg
  • Classification: Indoor use only
  • Operating temperature: +5°C to +40°C
  • Relative humidity: up to 80%
Description

With the CDND series, AMETEK CTS offers coupling and decoupling networks for feeding in differential interference. The Teseq CDND M316-2 is designed for differential voltage testing in the frequency range from 2 kHz to 150 kHz according to IEC/EN 61000-4-19.

IEC/EN 61000-4-19 specifies the differential voltage test in the frequency range 2 kHz to 150 kHz. Teseq offers with CDND M316-2 a coupling/decoupling network for single phase mains application. It can be used for both application with and without protective earth connection. The CDND is fully complaint with the requirements of the standard and provides a simple and reliable method of injecting RF energy into the equipment under test (EUT).

Key Features

  • Coupling networks designed for voltage test IEC/EN 61000-4-19
  • Frequency range 2 kHz to 150 kHz
  • 4 mm banana sockets
  • M2 and M3 applications