Close
You have no items in your shopping cart.

Teseq GTEM 500 Test Cell

Manufacturer part number: GTEM 500
The GTEM 500 has a maximum septum height of 500 mm and is suitable for emissions and immunity testing.
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   0
+ -
$0.00Configurations
X

Available Configurations

Teseq GTEM 500 Test Cell 

A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 500 has a maximum septum height of 500 mm and is suitable for emissions and immunity testing.

Features: 

  • Emissions and immunity testing in a single, shielded environment
  • Meets basic standard: IEC/EN 61000-4-20
  • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
  • Meets standards for immunity testing: EN 60118-13
  • Ideal for design qualification and pre-certification
  • Max. septum height: 500 mm
  • Septum height at marker position: 433 mm
  • Dimension (LxWxH): 2.95 x 1.48 x 1.61 m
  • Weight: approx. 242 kg
  • Height H1 of cell corpus: 1.04 m
  • CISPR 14-1
  • IEC 61000-4-20
  • IEC 61000–6–3
  • IEC 61000–6–4
Description

Teseq GTEM 500 Test Cell 

A GTEM (Gigahertz Transverse Electro Magnetic) cell is a test site for efficiently performing both radiated immunity and emissions testing in a single, controllable and shielded environment. Compared to other test sites, GTEM testing is faster with high accuracy and excellent reproducibility. In principle, the GTEM cell is a coaxial line expanding pyramidally and having an impedance of 50 Ω. At its end, the line is terminated by a combination of termination resistors and RF absorbers designed and constructed to match the above mentioned impedance. The GTEM 500 has a maximum septum height of 500 mm and is suitable for emissions and immunity testing.

Features: 

  • Emissions and immunity testing in a single, shielded environment
  • Meets basic standard: IEC/EN 61000-4-20
  • Meets standards for emissions testing: CISPR 14-1, IEC 61000-6-3 and IEC 61000-6-4 for EUTs without connected cables
  • Meets standards for immunity testing: EN 60118-13
  • Ideal for design qualification and pre-certification