Close
You have no items in your shopping cart.

Teseq NSG 4070B Conducted and Radiated Immunity Test System

Manufacturer part number: NSG 4070B
The Teseq NSG 4070B Test System for Conducted and Radiated Immunity is a multi-functional device for carrying out EMC immunity tests with a frequency range of 9KHz to 1GHz.
PURCHASE
Available QTY Price
New:   0
+ -
$0.00
Used:   0
+ -
$0.00 Configurations
X

Available Configurations

Teseq NSG 4070B Test System for Conducted and Radiated Immunity 

The NSG 4070B is a multi-functional EMC immunity test system. Its wide frequency range from 9 kHz to 1 GHz and its modular design using internal or external amplifiers enable a large variety of applications including tests according to IEC/EN 61000-4-6. Powerful and easy to use firmware makes it possible to operate the NSG 4070 as a stand-alone unit. However, it can also be controlled remotely by external software as part of a system. Convenient test and measurement data transfer for documentation is provided by a USB stick which is plugged into the front panel.

Features:

  • Integrated signal generator 9 kHz to 1 GHz 
  • 3 power meter inputs 9 kHz to 1 GHz 
  • Integrated class A power amplifier module for different applications: 35 W, 150 kHz to 230 MHz; 40 W, 10 kHz to 400 MHz; 45 W, 9 kHz to 1 GHz ; 80 W, 150 kHz to 230 MHz 
  • Multiple EUT monitoring options 
  • 5,7“ TFT color display
  • Internal, menu-based control software 
  • Basic remote control software and report generator included
  • Optically decoupled remote control

Standard Accessories Included

RF

  • Frequency range: 9 kHz to 1 GHz
  • Resolution: 1 Hz
  • Reference frequency: 10 MHz
  • Aging: 25 ppm

RF Level

  • Level range: -60 dBm to +10 dBm
  • Resolution: 0.1 dB
  • Settling time: 10 ms

Amplitude modulation

  • Modulation depth: 0 to 100%
  • Modulation frequency range: 1 Hz to 50 kHz
  • Frequency resolution: 1 Hz

Pulse modulation

  • Rise / fall time (10% / 90%): < 1 μs
  • Modulation frequency range: 1 Hz to 50 kHz
  • Frequency resolution: 1 Hz
  • Duty cycle: 10% to 90%

External modulation

  • Delay time: < 1 μs / 180°
  • Period: min. 20 μs
  • Pulse width: min. 10 μs

Linear measurement range

  • channel 1: -35 dBm to +27 dBm
  • channel 2,3: -45 dBm to +20 dBm

Max. input / no damage

  • channel 1-3: +28 dBm
  • Noise level: >5 dB below the measurement range
  • Input return loss: >20 dB (below 500 MHz), >17 dB (500 MHz to 1 GHz)
  • Connector: BNC socket, 50 Ω
  • Accuracy 10 to 30°C:
  •   Ford FMC1278
  •   GM GMW3097
  •   IEC 61000-4-20
  •   IEC 61000-4-21
  •   IEC 61000-4-6
  •   IEC 62132
  •   ISO 11452-4
  •   MIL-STD-461 CS114
  •   Nissan 28400NDS
  •   Peugot PSA B21 7110
  •   Renault 36-00-808
Description

Teseq NSG 4070B Test System for Conducted and Radiated Immunity 

The NSG 4070B is a multi-functional EMC immunity test system. Its wide frequency range from 9 kHz to 1 GHz and its modular design using internal or external amplifiers enable a large variety of applications including tests according to IEC/EN 61000-4-6. Powerful and easy to use firmware makes it possible to operate the NSG 4070 as a stand-alone unit. However, it can also be controlled remotely by external software as part of a system. Convenient test and measurement data transfer for documentation is provided by a USB stick which is plugged into the front panel.

Features:

  • Integrated signal generator 9 kHz to 1 GHz 
  • 3 power meter inputs 9 kHz to 1 GHz 
  • Integrated class A power amplifier module for different applications: 35 W, 150 kHz to 230 MHz; 40 W, 10 kHz to 400 MHz; 45 W, 9 kHz to 1 GHz ; 80 W, 150 kHz to 230 MHz 
  • Multiple EUT monitoring options 
  • 5,7“ TFT color display
  • Internal, menu-based control software 
  • Basic remote control software and report generator included
  • Optically decoupled remote control