Teseq® offers the world’s most comprehensive range of EMC systems for immunity and emissions testing. They take great pride in our world-class research and development program, backed by state-of-the-art global manufacturing. Their membership in the relevant international committees demonstrates their commitment to the industry. Their network of direct sales offices, representatives and distributors offers market leading EMC expertise tailored to local needs in more than 30 different countries.
Their unique “modular” approach to EMC is focused on their customers’ business needs. By breaking down the barriers between traditionally separate test functions they can optimize the test process to help you bring products to market more quickly.
Impedance stabilization networks (ISN, or with CISPR 16-1-2 called AAN: asymmetric artificial network) are defined for measuring of conducted common mode disturbances at information technology equipment (ITE) as required in CISPR 22 and CISPR 32. The ISN is placed between the equipment under test (EUT) and auxiliary equipment (AE) or load which are necessary for the operation of the EUT.
Wide frequency range 10 kHz - 400 MHz High power handling (up to 1 kW) Ideal for automotive BCI testing e.g. ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 and manufacture‘s requirements Meets IEC/EN 61000-4-6 Replacement for CIP 36A & 37A as specified in Defence Standard 59-41
The Teseq Profline 2103-240 is an accurate and flexible single phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3, supporting testing on products consuming up to 11 Arms and 92 A peak @ 230 VAC.
The Teseq ProfLine 2130-208 is an accurate and flexible three phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3.
The Teseq ProfLine 2105-400 is an accurate and flexible single phase system designed to measure harmonics & flicker in accordance with IEC 61000-3-2 and IEC 61000-3-3.
The ITS 6006 consist of an integrated RF signal generator, RF switch and EUT monitoring interfaces. The unit is designed for various radiated EMC applications in the 80 MHz to 6 GHz frequency range. In addition to the generator, the system includes the AM and PM modulators necessary for EMC testing. The second generation, called ITS 6006B, includes 3 freely configurable pulse modulators (1 µs to 200 s) for radar pulse profiles as required e.g. by Ford FMC1278 or VW TL81000. The RF signal can be switched to one of four outputs, where up to four power amplifiers can be connected directly. Two RF switches are supplied for combining four amplifier into two antenna paths.
The calibration kit CAS ISN is made for function tests and remeasurements on impedance stabilization network (ISN) for unshielded balanced pairs. Measuring parameters are common mode (CM) impedancence, phase angle, voltage division factor, decoupling attenuation (isolation) and longitudinal conversion loss (LCL). Impedance stabilization networks (ISN) are defined in CISPR 22 and CISPR 16-1-2.
Designed for IEC/EN 61000-4-6 conducted RF immunity testing with switchable M2 or M3, types with 4 mm banana sockets, and a frequency range of 150 kHz–230 MHz.
The Teseq MD 4070 Monitoring Device 10 kHz to 400 (600) MHz is suitable for BCI testing per ISO 11452-4, RTCA/DO-160 section 20, MIL-STD-461 CS114 and various automotive standards
As specified in IEC/EN 61000-4-6, the KEMZ 801 EM Clamp utilizes a combination of inductive and capacitive coupling and can be used on almost any cable
The Teseq CAS 3025 burst/EFT pulse verification kit has been specially designed to comply with the new requirements of IEC/EN 61000-4-4:2004 to enable EMC engineers to verify their burst/EFT test generators periodically.
CDN 3043 3-phase coupling/decoupling network series as a competitively priced, high performance extension to the NSG 3040 multifunction generator series.
Teseq’s CDN 117 coupling-decoupling network enables convenient testing with surge pulses of 1.2/50 μs on data, signal or peripheral lines, as specified in many product standards.
Teseq’s artificial network HV-AN 150 is the first universal solution which covers several applications and standards in the Automotive, Airborne and MIL range.
Manufactured exactly in accordance with the drawings and specifications of ISO 7637-3 for capacitively coupling the transients onto cables and wiring harnesses. With its characteristic impedance of 50 Ω , connected to the generator via a coaxial cable and terminated on the far side with a 50 Ω load resistor.
New, high power density, design has allowed us to produce a 70 W 1 MHz to 1 GHz amplifier in a compact 3U package. With a minimum of 55 W of linear power this amplifier is ideal for RF immunity testing in a GTEM and for 3V/m testing with a wide range of available antenna.
The transversal electromagnetic mode which can be developped in the SL 50 strip line, provides the opportunity for doing EMC testing inside the strip line. The geometrical dimensions having a line impedance of Z = 50 Ω. At the end is required a 50 Ω termination.
Single Turn Magnetic field coil for field strengths up to 4 A/m continuous, 40 A/m Short term (5 s), 1200 A/m pulsed (8/20 us) , 1 x 1 m, as specified in IEC 61000-4-8 and IEC 61000-4-9