The Vanguard TRM-403 is a three phase transformer winding resistance meter that allows the user to connect all test cables to the transformer bushings. The unit will then measure the transformer resistance value for each of the phases without the need to disconnect and reconnect cables for each phase.

The TRM-403 can provide a fast and stable reading of very large transformers by utilizing a 60Vdc power supply. It is capable of outputting a selectable test current from 1A to 40A. Since the TRM-403 can accurately measure resistance from 1 micro-ohm to 500 Ohms, it can be used as a micro-ohm meter to measure EHV circuit breaker contact resistance, or for any low resistance measuring application.

  • Perform three phase test on a transformer without the need to switch cables
  • Can provide individual Delta winding resistance values
  • Can provide individual Wye (with no neutral) winding resistance values
  • Demagnetize transformer after test
  • Selectable test current from 1A to 40A
  • Computer control via RS-232C, USB, or Bluetooth interface
  • Built-in 2.5" wide thermal printer
Type:Portable transformer winding resistance meter
Physical Specifications:21” W x 17” H x 9” D (53 cm x 43 cm x 24 cm); Weight: 35 lbs (15.8Kg)
Operating Voltage:100 – 240 Vac, 50/60 Hz
Resistance Reading Range:1 micro-ohm to 500 Ohms
Accuracy:1 – 19,999 micro-ohms: ±0.5% reading, ±1 count
20 – 999 milliohms: ±1% reading, ±1 count
1 -2000 Ohms: ±1.5% reading, ±1 count
Test Current:1-40A in 1A increments
Test Voltage:4 input channels for measuring resistance
Input Channels:60 Vdc charging, 18V DC max during measurement
Display:Back-lit LCD (128 x 64 pixels), viewable in direct sunlight and low light levels
Printer:Built-in 2.5" wide thermal printer
Internal Data Storage:256 static test records (each can contain up to 111 readings) and 120 dynamic test records
External Data Storage:Up to 999 test records on external USB Flash drive.
Computer Interfaces:RS-232C, USB, Bluetooth
Safety:Designed to meet UL 61010A-1 and Can/CSA C22.2 No 1010.1092 standards
Environment:Operating: -10ºC to 50ºC (15ºF to +122ºF)
Storage: (-30ºC to 70ºC (-22ºF to +158ºF)
Humidity (MAX):90% RH @ 40˚ C (104˚ F) non-condensing
Altitude (MAX):2000m (6562 ft) to full safety specifications
Cables:Four 50-foot test cables, one LTC control cable, one ground cable, one power cord, one USB cable
Options:Shipping case
  • UL 61010A-1
  • CAN/ CSA C22.2 No. 1010.1-92
Description

Key Features and Functions

The Vanguard TRM-403 is a three phase transformer winding resistance meter that allows the user to connect all test cables to the transformer bushings. The unit will then measure the transformer resistance value for each of the phases without the need to disconnect and reconnect cables for each phase.

The TRM-403 can provide a fast and stable reading of very large transformers by utilizing a 60Vdc power supply. It is capable of outputting a selectable test current from 1A to 40A. Since the TRM-403 can accurately measure resistance from 1 micro-ohm to 500 Ohms, it can be used as a micro-ohm meter to measure EHV circuit breaker contact resistance, or for any low resistance measuring application.

  • Perform three phase test on a transformer without the need to switch cables
  • Can provide individual Delta winding resistance values
  • Can provide individual Wye (with no neutral) winding resistance values
  • Demagnetize transformer after test
  • Selectable test current from 1A to 40A
  • Computer control via RS-232C, USB, or Bluetooth interface
  • Built-in 2.5" wide thermal printer