Close
You have no items in your shopping cart.

Teledyne LeCroy WaveSurfer 3054 Oscilloscope

Manufacturer part number: WS3054
Teledyne LeCroy WaveSurfer 3054 Oscilloscope: 500MHz, 2GS/s (4GS/s Interleaved), Four-Channel DSO with 10.1-Inch Color Touch Screen LCD
PURCHASE
AvailableQTYPrice
New:   0
+ -
$0.00
Used:   2
+ -
$5,250.00Configurations
X

Available Configurations

OSCILLOSCOPE, 4 CHANNELS, 500 MHZ
30007608
$5250
OSCILLOSCOPE, 4 CHANNELS, 500 MHZ
30007936
Include Options
Function Generator
$5250
OPTIONS
NamePurchase
Bandwidth option$0.00
Function Generator$0.00
Trigger and Decode$0.00
Mixed Signal probe etc$0.00
Function Generator$0.00
Bandwidth upgrade from 500MHz to 750MHz$0.00

Teledyne LeCroy WaveSurfer 3054 Digital Sampling Oscilloscope

500MHz, 2GS/s (4GS/s Interleaved), Four-Channel DSO with 10.1-Inch Color Touch Screen LCD.

WaveSurfer 3000 oscilloscopes feature the MAUI advanced user interface with touch screen simplicity to shorten debug time. The advanced probe interface, upgradable bandwidth and multi-instrument capabilities provide maximum versatility and investment protection.

MAUI User Interface

MAUI is the most advanced oscilloscope user interface developed to put all the power and capabilities of the modern oscilloscope right at your fingertips.

  • Designed for touch: all important oscilloscope controls are accessed through the intuitive touch screen
  • Made for simplicity: time-saving shortcuts and intuitive dialogs simplify setup
  • Built to solve: a deep set of debug and analysis tools help identify problems and find solutions quickly
  • One probe per channel
  • Manuals
  • Power cord
  • All standard accessories

Vertical System

  • Bandwidth: 500MHz
  • Risetime: 800ps typical
  • Input Channels: four
  • Bandwidth Limiters: 20MHz, 200MHz
  • Input Impedance: 50Ω ±2.0%, 1MΩ ±2.0%; 16pF
  • Input Coupling, 50Ω: DC, GND
  • Input Coupling, 1MΩ: AC, DC, GND
  • Maximum Input Voltage, 50Ω: 5Vrms, ±10V Peak
  • Maximum Input Voltage, 1MΩ: 400V (DC + Peak AC ≤10kHz)
  • Channel-Channel Isolation: ≥52dB from DC to 100MHz
  • Vertical Resolution: 8-bits
  • Sensitivity, 1MΩ: 2mV/div to 10V/div
  • Sensitivity, 50Ω: 2mV/div to 1V/div
  • DC Gain Accuracy: ±1.5%
  • Offset Range, 50Ω: 1mV to 19.8mV: ±2V, 20mV to 100mV: ±1V, 102mV to 198mV: ±20V, 200mV to 1V: ±50V
  • Offset Range, 1MΩ: 1mV to 19.8mV: ±2V, 20mV to 100mV: ±5V, 102mV to 198mV: ±20V, 200mV to 1V: ±50V, 1.02V to 1.98V: ±200V, 2V to 10V: ±400V
  • Offset Accuracy: ±(1.0% of offset value + 1.5%FS + 1mV)

Analog Acquisition System

  • Sample Rate, Single-shot: 2GS/s (4GS/s interleaved)
  • Sample Rate, Repetitive: 50GS/s
  • Record Length: 10Mpts/ch, all channels
  • Acquisition Modes: Real Time, Roll, RIS (Random Interleaved Sampling), Sequence (Segmented Memory up to 1,000 segments with 1Οs minimum intersegment time)
  • Real-Time Timebase Range: 1ns/div to 50s/div
  • RIS ModeTimebase Range 1ns/div to 10ns/div
  • Roll Mode Timebase Range Up to 50s/div (roll mode is user selectable at ≥100ms/div)
  • Timebase Accuracy ±10ppm measured over >1ms interval

Digital Vertical and Acquisition System (WS3K-MSO Option Only)

  • Input Channels: 16 Digital Channels
  • Threshold Groupings, Pod 1: D7 - D0
  • Threshold Groupings, Pod 2: D15 - D8
  • Threshold Selections: TTL(+1.4V), 5V CMOS (+2.5V), ECL (-1.3V), or User Defined
  • Maximum Input Voltage: ±30V Peak
  • Threshold Accuracy: ±(3% of threshold setting + 100mV)
  • Input Dynamic Range: ±20V
  • Minimum Input Voltage Swing: 500mVpp
  • Input Impedance (Flying Leads): 100kΩ; 5pF
  • Maximum Input Frequency: 125MHz
  • Sample Rate: 500MS/s
  • Record Length: 10MS - 16 Channels
  • Minimum Detectable Pulse Width: 4ns
  • Channel-to-Channel Skew: ±(1 digital sample interval)
  • User defined threshold range: ±10V in 20mV steps

Triggering System

  • Modes: Normal, Auto, Single, Stop
  • Sources: Any input channel, External, Ext/5, or line; slope and level unique to each source (except for line trigger)
  • Coupling Mode: AC, DC, LF Rej, HF Rej
  • Pre-trigger Delay 0 to 100% of Full Scale
  • Post-trigger Delay 0 to 10,000 Divisions
  • Hold-Off: 10ns to 20s or 1 to 1000,000,000 events
  • Internal Trigger Level Range: ±4.1 Divisions
  • External Trigger Level Range, Ext: ±610mV
  • External Trigger Level Range, Ext/5: ±3.05V
  • Trigger Types: Edge, Width, Logic (Pattern), TV (NTSC, PAL, SECAM; HDTV 720p, 1080i, 1080p), Runt, Slew Rate, Interval (Signal or Pattern), Dropout, Qualified (State or Edge); External and Ext/5 support edge trigger only

Measure, Zoom, Math Tools

  • Measurement Parameters: Up to six of the following parameters can be calculated at one time on any waveform: Amplitude, Area, Base, Delay, Duty Cycle, Fall Time (90%-10%), Fall Time (80%-20%), Frequency, Maximum, Mean, Minimum, Overshoot+, Overshoot-, Peak-Peak, Period, Phase, Rise Time (10%-90%), Rise Time (20%-80%), RMS, Skew, Standard Deviation, Top, Width+, Width- (Statistics and histicons can be added to measurements; Measurements can be gated)
  • Zooming: Front panel QuickZoom button or touch screen or mouse can be used to draw a box around the zoom area
  • Math Functions (up to two of the following functions can be calculated at one time): Sum, Difference, Product, Ratio, Absolute Value, Average, Derivative, Envelope, Floor, Integral, Invert, Reciprocal, Rescale, Roof, SinX/x, Square, Square Root, Trend, Zoom and FFT (up to 1Mpts with power spectrum output and rectangular, VonHann, and FlatTop windows)

Probes

  • Quantity: One PP020 Probe (5mm) per channel
  • Probing System: BNC and Teledyne LeCroy ProBus for Active voltage, current and differential probes

Interface

  • USB, Host: four
  • USB, device: one USBTMC
  • Ethernet Port: 10/100Base-T Ethernet interface (RJ-45 connector)
  • External Monitor Port Standard DB-15 connector (resolution: 1024x600)
  • Removable Storage: one MicroSD Port; 8GB microSD card installed standard
  • GPIB Port: one (optional)

Power Requirements

  • Mains: 100 to 240VAC ±10% @ 50Hz to 60Hz; 100 to 120VAC ±10% @ 400Hz to 420Hz ±5%; Automatic Voltage Selection
  • Power Consumption, nominal: 100VA
  • Power Consumption, max: 150VA (with all PC peripherals, digital leadset and active probes connected to four channels)

WaveSource Function Generator (Optional)

  • Max Output Frequency: 25MHz
  • Channels: one
  • Frequency Resolution: 125MS/s
  • Vertical Resolution: 14-bit
  • Vertical Range: ±3V (HiZ); ±1.5V (50Ω)
  • Waveform Types: Sine, Square, Pulse, Ramp, Noise, DC
  • Frequency, Sine: 1µHz to 25MHz
  • Frequency, Square/Pulse: 1µHz to 10MHz
  • Frequency, Ramp/Triangular: 1µHz to 300KHz
  • Noise: 25MHz (-3dB)
  • Frequency Resolution: 1µHz
  • Frequency Accuracy ±50ppm, over temperature
  • Aging ±3ppm/year, first year
  • Amplitude, HiZ: 4mVpp to 6Vpp
  • Amplitude, 50Ω: 2mVpp to 3Vpp
  • Vertical Accuracy: ±(0.3dB + 1mV)
  • Amplitude Flatness: ±0.5dB
  • DC Offset Range: ±3V (HiZ); ±1.5V (50Ω)
  • DC Offset Accuracy: ±(1% of offset value ±3 mV)
  • Impedance: 50Ω ±2%
  • Protection: Short-circuit protection
  • Sine Spectrum Purity, SFDR (Non Harmonic) @1.265Vpp, DC to 1MHz: -60dBc
  • Sine Spectrum Purity, SFDR (Non Harmonic) @1.265Vpp, 1MHz to 5MHz: -55dBc
  • Sine Spectrum Purity, SFDR (Non Harmonic) @1.265Vpp, 5MHz to 25MHz: -50dBc
  • Sine Spectrum Purity, Harmonic Distortion @1.265Vpp: DC to 5MHz: -50dBc
  • Sine Spectrum Purity, Harmonic Distortion @1.265Vpp: 5MHz to 25MHz: -450dBc
  • Square/Pulse Rise/fall time 24ns (10% to 90%)
  • Square/Pulse Overshoot 3% (typical to 1kHz, 1Vpp)
  • Square/Pulse Pulse Width 50ns min
  • Square/Pulse Jitter 500ps + 10ppm of period (RMS cycle to cycle jitter)
  • Ramp/Triangle Linearity: 0.1% of Peak value output (typical: 1kHz, 1Vpp, 100% symmetric)
  • Ramp/Triangle Symmetry: 0% to 100%

Protocol Analysis with Serial Trigger and Decode (WS3K-EMB Option)

  • Color-coded overlay presenting information in binary, hex, or ASCII
  • Decode long waveforms and zoom in to see precise byte-by-byte decoding
  • Use the serial trigger to isolate specific addressed and data
  • Decoded information can be conveniently displayed in an interactive table

WaveSurfer 3000-Series Option/Accessory Pricing

  • WS3K-FG Function Generator Option: $500
  • WS3K-MSO MSO Option Includes lead set and software option card: $1,500
  • WS3K-EMB I2C, SPI, UART, RS232 Trigger and Decode: $990
  • WS3K-Rack Rack Mount Kit: $490
  • WS3K-Softcase Softcase: $475

Description

Teledyne LeCroy WaveSurfer 3054 Digital Sampling Oscilloscope

500MHz, 2GS/s (4GS/s Interleaved), Four-Channel DSO with 10.1-Inch Color Touch Screen LCD.

WaveSurfer 3000 oscilloscopes feature the MAUI advanced user interface with touch screen simplicity to shorten debug time. The advanced probe interface, upgradable bandwidth and multi-instrument capabilities provide maximum versatility and investment protection.

MAUI User Interface

MAUI is the most advanced oscilloscope user interface developed to put all the power and capabilities of the modern oscilloscope right at your fingertips.

  • Designed for touch: all important oscilloscope controls are accessed through the intuitive touch screen
  • Made for simplicity: time-saving shortcuts and intuitive dialogs simplify setup
  • Built to solve: a deep set of debug and analysis tools help identify problems and find solutions quickly
Product tags