Key Features and Functions
The 2503AH Analyzers measure power, voltage, and current up to 500 kHz with premier precision. Available parameters include V, A, W, Power Factor, Crest Factor, K Factor, THD, Harmonics, Phase, VA, VAR, W.Hr, Triplens, Impedance, Inrush, Mean-Peak Values, EfficiencyLoss, etc. Vitrek power analysis instruments have set the standard for production testing. Independent channel control and unparalleled flexibility and speed have made the 2503AH-3CH the instrument of choice in 3-phase power analysis. The 2503AH-1CH/2CH offers cost-effective solutions for single or two-phase applications such as power supply and appliance testing.
- 18-bit, 500 kHz sampling speed provides 0.05% basic accuracy
- Ultra-fast FFT’s per channel produce measurements in 10 ms
- 3000 V Peak, 50 Amp Peak internal shunt and Hall effect CT’s
- Pre-configured for ballast, motor, power supply and appliance tests
- Real-time, ultra-fast, harmonic analysis
- Application specific configurations
- External CT and PT capability ratio: 0.000001 - 1000000 to 1, for A/V, A/A or V/V
- Frequency Measurement: 500 µHz to 500 kHz, 0.01% of reading
- Measurement Period: User defined from 1 mSec to 27.8 hours
- Watt, VA & VAR Accuracy highest of V Amp error or Amp V error yields max. error for either Watts, VA, or VAR
- Accumulation accuracy WHr, VAHr, AHr up to 9999.9 GWHr/GVAHr
- Timing Accuracy: 0.01% + 10 mSec. start/stop error